background image

 
 
 
 

Page 3 (12) 

 

www.ernitec.com 

Table of Contents 

Page 

 

Standard Models ...................................................................................................................................................... 1

 

Highlights .................................................................................................................................................................. 1

 

1

 

Introduction ........................................................................................................................................ 4

 

2

 

Mounting and Installation ................................................................................................................. 4

 

3

 

Connecting the PIR ............................................................................................................................ 4

 

4

 

Field of View ....................................................................................................................................... 5

 

5

 

Alignment ........................................................................................................................................... 5

 

6

 

Sensitivity Settings for Range and Mounting Height ..................................................................... 6

 

7

 

Adaptive Threshold Discrimination (ATD) ...................................................................................... 6

 

8

 

Anti Vandal Function ......................................................................................................................... 7

 

9

 

LED ...................................................................................................................................................... 7

 

10

 

Alarm Management ............................................................................................................................ 7

 

11

 

Alarm Time ......................................................................................................................................... 7

 

12

 

Internal Temperature Compensation ............................................................................................... 7

 

13

 

Internal Heater (H version only) ....................................................................................................... 7

 

14

 

External Sensitivity Adjustment via RS 485 Data Bus ................................................................... 8

 

15

 

Signal Processing .............................................................................................................................. 8

 

16

 

Accessories ........................................................................................................................................ 8

 

16.1

 

Interface Module PIRIF 485/2 and Installation Software .............................................................................. 8

 

16.2

 

Pole Mount Hardware ZA P-L1 ..................................................................................................................... 8

 

17

 

Maintenance ....................................................................................................................................... 9

 

18

 

General Comment on the Eagle PIR ................................................................................................ 9

 

19

 

Appendix Electronic Board and Terminal Block........................................................................... 10

 

19.1

 

Terminal Block ............................................................................................................................................ 10

 

19.2

 

Dip Switches ............................................................................................................................................... 10

 

20

 

Appendix Two Way Communication RS 485 ................................................................................. 11

 

20.1

 

Introduction ................................................................................................................................................. 11

 

21

 

Appendix Installation Software ...................................................................................................... 11

 

21.1

 

Introduction ................................................................................................................................................. 11

 

21.1.1

 

Application of the Installation Software ....................................................................................................... 11

 

22

 

Appendix Specification ................................................................................................................... 12

 

22.1

 

Mechanical Dimensions .............................................................................................................................. 12

 

 

 

Содержание Eagle PIR-100

Страница 1: ...Nominal Range 120 m 400 feet PIR 100H High Performance Nominal Range 150 m 500 feet Highlights Gap Free Coverage with Creep Zones 4 Meter 13 Feet Mounting Height Advanced Tamper Detection Low Power Co...

Страница 2: ...Page 2 12 www ernitec com www ernitec com...

Страница 3: ...Heater H version only 7 14 External Sensitivity Adjustment via RS 485 Data Bus 8 15 Signal Processing 8 16 Accessories 8 16 1 Interface Module PIRIF 485 2 and Installation Software 8 16 2 Pole Mount H...

Страница 4: ...d for wall mounting using screws For pole mounting the original accessory ZA P L1 is available pole mounting bracket with two strap bands for poles of 4 16 cm diameter For further information please r...

Страница 5: ...ve on the top of the detector This line of sight corresponds to the upper edge of the detection pattern Accurate fine alignment is easily achieved with the help of the Universal Telescopic Sight ZA P...

Страница 6: ...eeding a certain minimum value will activate the ATD and increase the threshold levels depending on its strength The time constants for increase and decrease are chosen in a way to adapt to gradual ch...

Страница 7: ...over RS 485 communication All the detectors connected to the same data bus provide all the information relevant to an alarm in a defined protocol frame For further information please contact the manuf...

Страница 8: ...or repeated movements in the field of view the exponential decay of the threshold level to its original value will take app 1 2 minutes from the end of the event Once the threshold level value has be...

Страница 9: ...on is a function of thermal contrast speed and size of a target crossing the field of view Contrast conditions can vary significantly in the course of the day and year Detection depends also on the se...

Страница 10: ...d Output Transistor OC Not used GND Supply voltage 10 5 30 V DC 24 V AC 1 2 3 4 5 6 7 8 50 mA 6 V RS 485 A B 4 7 k 100 mA Sensitivity SW1 SW2 PIR 100 PIR 100H ON ON SW settings ON OFF HW setting maxim...

Страница 11: ...nk it is necessary that the detectors have different addresses IDs For operation with a standard PC a converter to RS 485 is required The interface box is available as accessory 21 1 1 Application of...

Страница 12: ...Weight app 900 g 2 0 lbs incl mounting bracket Cable Feeds 2 x M 16 with cable clamp Outer Cable Diameter 4 5 10 mm 0 18 0 40 inch Electrical Supply Voltage 10 5 30 V DC 24 V AC 15 Current Consumption...

Отзывы: