8  Anti Vandal Function 

The PIR is equipped with a sophisticated 

protection against vandalism

. These detectors can sense certain 

changes of their alignment from the original position as set during the installation. A change of the detector’s 
alignment generates a permanent alarm 

until the detector’s alignment is back in its original position or until 

the position has purposely been reset

When using the alarm management with RS 485 communication a vandal alarm will be identified separately. 
After the turn-on time of typ. 60 seconds from power on, the detector determines and stores its alignment position 
(only with detector cover closed). 
After opening and closing the cover with the unit powered on, the detector determines its alignment position and 
stores the position value after 5 minutes again without having the detector in permanent alarm state.  
The anti vandal sensor can be reset remotely with the setup program (takes app. 10 seconds) or with a power off-
on (60 seconds). 

Hardware Mode:  

 

When operating the detector in the HW mode, the anti vandal function is activated by setting DIP – Switch 6 to „on“. 

Software Mode: 

 

Operating the detector in the SW mode, the anti vandal function is activated by means of setting of the 
corresponding parameter in the settings of the setup program to „on“. 

9 LED 

The electronic board is fitted with a dual LED having a red and green colour side. This can be monitored during 
installation while the cover is open. 

ƒ

 

The red LED indicates whether the detector is in alarm state or not  

ƒ

 

The green LED flashing at 2 Hz frequency indicates the detector ready state. 

During the turn-on time the red LED is on. 

10 Alarm Management 

The PIR features an alarm management function over RS 485 communication. All the detectors connected to the 
same data bus provide all the information relevant to an alarm in a defined protocol frame. For further information 
please contact the manufacturer. 

11 Alarm Time 

Alarm time per event is determined by the duration of the detected event and depends on the shape and amplitude 
of the alarm signal. Individual alarm pulses have a minimum time of app. 2.5 s. 

12  Internal Temperature Compensation 

The PIR is detecting radiation differences of a target against its background. In the course of the day and year the 
contrast of a person will vary considerably and affect the signal strength. To compensate for this contrast variation, 
the PIR has internal temperature compensation with maximum sensitivity at app. 30°C (where the contrast of a 
human target is weakest) and gradual reduction at higher and lower temperatures. 

 

When installing a unit the internal temperature may take up to 30 minutes or more to stabilise to the actual 
external temperature. Sufficient time should be given to the PIR to reach the correct internal temperature and 
sensitivity before performing walk tests. 

During the initial period of operation it is strongly recommended that walk tests are repeated and signals monitored 
under various weather conditions such as high and low temperatures, wind fog, snow, rain etc. to obtain 
comparative data and information on the effects of environmental conditions on detection and nuisance alarm 
probabilities for this particular site. Fine-tuning of the detector based on this data by changing the sensitivity 
settings may optimise the performance. 

13  Internal Heater (H version only) 

A regulated heater connected to the electronic board and powered by the supply voltage of the PIR-100H prevents 
the optical surfaces from fogging or frosting and maintains the internal temperature at optimal levels. 

Switch 6 

Anti Vandal Function 

 

off 

off 

 

on 

on 

Factory Setting 

Содержание Eagle PIR-100

Страница 1: ...Nominal Range 120 m 400 feet PIR 100H High Performance Nominal Range 150 m 500 feet Highlights Gap Free Coverage with Creep Zones 4 Meter 13 Feet Mounting Height Advanced Tamper Detection Low Power Co...

Страница 2: ...Page 2 12 www ernitec com www ernitec com...

Страница 3: ...Heater H version only 7 14 External Sensitivity Adjustment via RS 485 Data Bus 8 15 Signal Processing 8 16 Accessories 8 16 1 Interface Module PIRIF 485 2 and Installation Software 8 16 2 Pole Mount H...

Страница 4: ...d for wall mounting using screws For pole mounting the original accessory ZA P L1 is available pole mounting bracket with two strap bands for poles of 4 16 cm diameter For further information please r...

Страница 5: ...ve on the top of the detector This line of sight corresponds to the upper edge of the detection pattern Accurate fine alignment is easily achieved with the help of the Universal Telescopic Sight ZA P...

Страница 6: ...eeding a certain minimum value will activate the ATD and increase the threshold levels depending on its strength The time constants for increase and decrease are chosen in a way to adapt to gradual ch...

Страница 7: ...over RS 485 communication All the detectors connected to the same data bus provide all the information relevant to an alarm in a defined protocol frame For further information please contact the manuf...

Страница 8: ...or repeated movements in the field of view the exponential decay of the threshold level to its original value will take app 1 2 minutes from the end of the event Once the threshold level value has be...

Страница 9: ...on is a function of thermal contrast speed and size of a target crossing the field of view Contrast conditions can vary significantly in the course of the day and year Detection depends also on the se...

Страница 10: ...d Output Transistor OC Not used GND Supply voltage 10 5 30 V DC 24 V AC 1 2 3 4 5 6 7 8 50 mA 6 V RS 485 A B 4 7 k 100 mA Sensitivity SW1 SW2 PIR 100 PIR 100H ON ON SW settings ON OFF HW setting maxim...

Страница 11: ...nk it is necessary that the detectors have different addresses IDs For operation with a standard PC a converter to RS 485 is required The interface box is available as accessory 21 1 1 Application of...

Страница 12: ...Weight app 900 g 2 0 lbs incl mounting bracket Cable Feeds 2 x M 16 with cable clamp Outer Cable Diameter 4 5 10 mm 0 18 0 40 inch Electrical Supply Voltage 10 5 30 V DC 24 V AC 15 Current Consumption...

Отзывы: