Verarbeitungsspezifikation MaxiBridge CSI
/
Processing Specification MaxiBridge CSI
erstellt: Darius Clement
geprüft: Bernd Schmitt
freigegeben: Achim Schoch
am: 01.12.2017
Version 6
IMS Verarbeitungsspezifikationen
Seite 21 von 26
Pull-out forces according to IEC 60352-2 respectively LV214 PG 10
Minimum pull-out forces are listed in table 2.
Tear-off characteristics
The tear-off characteristics has to be assessed positively, if the single strands tear-off irregularly behind the
bellmouth once the pull-out force (see table 2 ) has been achieved.
Figure 8
The single strands tear-off directly behind the bellmouth: overpressed.
The single strands do not tear-off and are pulled out of the crimp: underpressed.
Illustration of an optimal tear-off behavior