GB-20
D
GB
F
NL
I
E
▷
If the burner control unit responds in a different
way to that described, a fault has occurred, see
page 12 (Assistance in the event of malfunc-
tion).
CAUTION
The fault must be remedied before the system may
be operated.
Checking burner operation
Switch on the burner control unit ACU.
Select operating mode
2
Heating.
Check the CO
2
value, see page 9 (Adjusting
Accessories
Air diffuser
The air diffuser allows the flow of heated air to be
channelled in the required direction. By bending the
plates in the housing, the air flow can be aligned
horizontally and vertically.
CAUTION
Ensure that the plates are always aligned so that the
air can flow out properly. If the air flow is blocked,
the heater will overheat.
Order No.: N70000001
Room thermostat
Use a room thermostat with a hysteresis of ± 1°C,
230 V, Type TH 215.
35
30
25
20
15
10
5
0
°
C
TH215
Order No.: N50260145
Pressure reducer
Pressure reducer for LPG.
RECA 1.5 bar to 50 mbar, 2 x ½" internal thread
connection, 10 kg/h, Order No.: N50260023.
Manual valve
Manual valve for gas.
2 x ½" internal thread connection,
Order No.: N50260019.
½" internal and external thread connection,
Order No.: N50260027.
BCSoft
There are two PC opto-adapters (PCO) available for
the connection to the PC and BCSoft:
Wireless connection using Bluetooth technology:
Bluetooth adapter PCO 300
Including BCSoft CD-ROM,
Order No.: N70000066.
Cable connection via USB port:
Opto-adapter PCO 200
Including BCSoft CD-ROM,
Order No.: N70000065.
▷
See operating instructions PCO 200 and
PCO 300 at http://www.docuthek.com.
▷
The current BCSoft software can be downloaded
from our Internet site at http://www.docuthek.com.
To do so, you need to register in the DOCUTHEK.