# VSH400PLC090909
- 12 -
6.7 POWER SUPPLY TO THE EXTERNAL EQUIPMENT
In order to supply power to the external equipment connected to the hydraulic head, go
to the HEAD menu, Fig. 22. The program starts the module controlling the power
supply to the hydraulic high pressure pipe ending with a quick coupler.
Fig.22
6.8 FOLDING AND UNFOLDING THE TABLETOP
To unfold the tabletop:
•
fold up the extended measurement bar to its basic position (if any),
•
press the button TABLETOP FOLDING (SKŁADANIE BLATU) on the control
panel (the button releases for 5 seconds the blockade of the tabletop blocking
bolts)
•
release the bolts and lift the tabletop to the working position
•
bolt the tabletop
•
The “TABLETOP FOLDING” button is available at any time of the station
operation, but it is only active when the “extended measurement bar” is in its
basic position.
To fold the tabletop:
•
fold up the extended measurement bar to its basic position (if any),
•
press the button TABLETOP FOLDING on the control panel (the button
releases for 5 seconds the blockade of the tabletop blocking bolts)
•
release the bolts and lower the tabletop to the resting position
•
bolt the tabletop
Note:
The station is equipped with safety devices, but you must not try to fold up
the tabletop is the “extended measurement bar” is not in its basic position.
This may result in damaging the measurement bar.
An additional tabletop is available as an option or as part of the standard in the models
of the SH400PLC PLATINUM series.
An extended measurement bar available only with an additional tabletop is available
as an option or as part of the standard in the models of the SH400PLC PLATINUM
series.