General Description
Technical Data
WARNING
This control is capable of variable output voltage over
a wide range of frequencies. This model should only be
run at the factory set frequency. If modification in output
frequency is needed, we suggest that the user contact
Eriez first. After switching unit off, some components
may still be charged due to capacitance. Wait at least
five (5) minutes before opening the cover to allow
capacitors to discharge.
This control is a variable voltage frequency controller. A front
panel display and keypad make set-up and operation an
easy task. This control can be used for manual or remote set
point control. Other features include; amplitude regulation and
track control. Control of the vibratory feeder is accomplished
by using sinusoidal waveform impulses (modulated). This
method results in quiet operation.
DESCRIPTION
FREQUENCY CONTROL (RE)
Input Voltage
115/230 V 50/6.0 Hz
Output voltage
0-110 or 0-220 VAC
Output current
12.0 A max.
Soft start
0…4. sec.
Sensor supply
24. V, 25Ma
Switch on time delay
0…10 sec.
Switch off time delay
0…10 sec.
Empty time
30…18.0 sec.
Set point source
Keys/ 0…10 V, 0(4.)…20mA DC
Enable
12-24. V, DC/ Switch
Status relay
Form “C” 250V, 1A
Operating temperature
0-113 degrees F