TROUBLESHOOTING
Page 15
PROBLEM
CAUSE
SOLUTION
Improper brine draw
Low operating pressure
Check operating pressure; must be higher than 1,4
bar
Plugged injector and/or brine draw restrictor
Clean injector and/or brine draw restrictor
Plugged injector filter
Clean injector filter
Restricted drain line
Verify drain line for kinks or restrictions
Restricted brine line
Verify brine line for kinks or restrictions
Leak in brine line
Verify brine line and connections for air leakage
No water in brine tank
Refer to problem “Control v
alve fails to refill brine
tank”
Fast rinse solenoid remains open
Verify operation of fast rinse solenoid