MINI-LINK E and E Micro
•
Alarm outputs, see table below
•
System alarm output: TTL level
Table 46
External alarm inputs
External contact
Open to earth
Closed to earth
Threshold current
< 0.1 mA
> 0.5 mA
Maximum values from
alarm source
12 V
1 mA
Table 47
Alarm outputs
Internal three-pole
relay contact
Open to earth
Closed to earth
Maximum values from
alarm source
60 V
200 mA (< 100 m )
Cross-connect
The total cross-connect switching capacity is 64 Mbit/s or 1 043 time slots. 120
time slots (correspond to 4x2 Mbit/s) can be switched at nx8 kbit/s level.
Switch Time for Ring Configuration
50 ms
153