2.2.4
Configurations
2.2.4.1
Unprotected Terminal (1+0)
As a minimum a 1+0 terminal consists of:
•
RAU
•
Antenna
•
AMM 1U
•
MMU
•
Coaxial cable for interconnection
For traffic capacities 8x2, 17x2 and 4x8+2, an SMU is required. An SAU can be
added to the AMM to provide additional alarm and control interfaces, service
channels and other customer specific applications.
MMU
AMM 1U
2x2, 4x2,
8, 2x8 or
34+2 Mbit/s
3510
Figure 14
1+0 configuration. The MMU can be installed in an AMM 1U
(AMM 2U-3 if SAU is required).
4492
Figure 15
1+0 configuration for 8x2, 4x8+2 and 17x2 Mbit/s capacities
13