The state of the control shelf after starting or stopping
functions is dependent upon the function in question and
external control shelf signals (e.g., keying/unkeying a local
mic). Refer to the Function Description section for specific
details.
Select a specific function as listed in Figure 5 and enter the
corresponding number. Then press the "A" key to start (acti-
vate) the function.
To stop the selected function, press the "C" key.
To reset the station’s programmed personality defaults,
toggle the RESET switch located on the front of the Power
Module.
FUNCTION DESCRIPTIONS
(See Figure 5)
Repeat Disable
Start: Disable the repeater function.
Stop: Restore the original EEPROM setting.
Tx Disable
Start: Disable the transmitter.
Stop: Restore the original EEPROM setting.
Function
Key
Display
Power up
handset
None
Enter function
select mode
Input desired
function; e.g. 7
for CGD Enable
To start function
To stop function
To return to
function
select mode
F SEL 7
MENU
START 7
F SEL
F SEL
STOP 7
CLR
PRS
7
C
A
FNC
Figure 4 - System Functions
If the function was programmed to be active, starting it
will have no effect.
NOTE
In some functions, the stop key will actually reset the
station to its originally programmed state rather than
stop the selected function. Consult the detailed expla-
nations of the function to determine its actual opera-
tion. END will return the handset to the top menu, and
like the CLR function, will leave the station in the
condition set by the different function commands.
NOTE
NUMBER
FUNCTION
30
Repeat Disable
32
Tx Disable
34
CG Encode Disable
36
CG Decode Disable
37
RUS Mute
38
CG Monitor
39
Remote PTT
40
Local PTT
41
External PTT
42
Morse Code
44
Battery Alarm Disable
45
Test Tone
46
System Reset
47
CCT Disable
48
RUS Disable
49
Scan Enable
50
Scan Disable
58
Main Rx Enable
59
Main Rx Disable
60
Aux Rx Enable
61
Aux Rx Disable
64
Aux Control 1 On
65
Aux Control 1 Off
71
Priority Scan Disable
75
Scan Inhibit
96
Voting Tone Enable/
Voting Tone Disable
Figure 5 - Function Chart
LBI-38599