background image

The Rx Meter and Tx Meter functions in the MASTR IIe

are used with the Meter Switching kit, 19B226293G1.  See
LBI-4848.

In the MASTR III, PWR returns a voltage proportional to

the reflected power in the circulator.  Rx is the RSSI line from
the IF module.  Tx and EXT are external metering points on
the MASTR III and are brought to a header on the MIII
backplane for use in special functions.  Otherwise, they are
available for the operator to use in various metering applica-
tions.

The display provides the appropriate abbreviations and

current level. These readings are updated every 2 seconds (see
Figure 8).

The Handset can also present these data in decimal format.

By pressing the "B" key while in the metering mode, the
handset will toggle from volts to decimal. The decimal meas-
urement range is 0 to 255.

Decimal data are presented with no spaces between the

numbers. The default is analog voltages.

CHANNEL SELECT MODE

In multi-frequency stations, the Utility Handset can change

the selected channel.

To enter the Channel Select Mode from the main menu,

press the "C" key.

The display will show the current channel. To change

channels press the channel number desired (1-4). Assuming a
two channel station with channel 1 as the current channel,
pressing the 2 key will result in the handset displaying "C SEL
2". In order to complete this channel selection, the C key must
be pressed. Now the handset will display "CHAN 2".

If desired, adjustments to the Channel Guard Level settings

for channel 2 may now be made. It should be noted that when
the handset is in the Channel Select Mode ("C SEL x"), any
entry may be discarded by pressing the CLR key. Pressing the
CLR key a second time will return the handset to the "MENU"
display.

The Channel Select Mode may also be entered from the

Channel Display Mode ("CHAN x") by using the "C" key. The
resulting display is "C SEL". Channel selection may proceed
as described above. Also note that when in the Channel Select
Mode, the previously selected channel may be redisplayed by
entering an invalid channel number (which includes a blank
selection).

REMOTE STATION ADJUSTMENTS VIA
MODEM

Function

Key

Display

Power up
handset

None

Enter metering
mode

To select
power

To select
Rx

To select
Tx

To select
external

To toggle to
decimal display

 

Numbers read with no spaces

 

in decimal:

XXX

B

GHI

4

MENU

EXT X XX

TX X XX

RX X XX

PWR X XX

METER

DEF

3

ABC

2

QZ

1

B

Figure 8 - Metering Switches

Function

Key

Display

Power up
handset

None

Display Current
channel

To select new
channel

GHI

4

MENU

C SEL X

CHAN X

DEF

3

ABC

2

QZ

1

C

C

Figure 9 - Channel Select Switches

LBI-38599

10

Содержание MASTR IIe

Страница 1: ...LBI 38599E Mobile Communications MASTR IIe UTILITY HANDSET Maintenance Manual...

Страница 2: ...10 Remote Station Adjustments Via Modem 10 Maintenance 11 APPENDIX A A 1 Copyright March 1991 Ericsson GE Mobile Communications Inc SPECIFICATIONS POWER SUPPLY Nominal 12 5 Vdc Range 10 to 16 Vdc No f...

Страница 3: ...hardware includes a EEPROM contain ing the operating characteristics or personality of the Control Shelf The contents of the EEPROM can be changed only with the use of the Utility Handset or with a p...

Страница 4: ...n the side of the handset toggle the RESET switch on the front of the MASTR IIe Power Module This tells the Control Module there is a handset present Successful power up will cause the display to show...

Страница 5: ...M light on the display when Scan is active SYSTEM FUNCTIONS The Utility Handset may be used to toggle special func tions in the station see Figure 4 To enter the Function Select Mode from the main men...

Страница 6: ...on To return to function select mode F SEL 7 MENU START 7 F SEL F SEL STOP 7 CLR PRS 7 C A FNC Figure 4 System Functions If the function was programmed to be active starting it will have no effect NOT...

Страница 7: ...ing test tone Stop Stop sending test tone Comment The test tone frequency is 1000 Hertz Soft Boot Start Toggles software reset Stop No function Carrier Control Timer Disable Start Disable the carrier...

Страница 8: ...5 5 0 255 6 0 255 2 VTG CT MCTX 1 0 127 2 0 32767 4 0 255 3 PA RG SQ 1 0 99 2 0 32767 3 0 99 On each Pot Page the unused key numbers will have no effect To enter the Adjust Potentiometer Mode from the...

Страница 9: ...providing a readout of various DC voltages in a properly configured station To enter the Metering Mode from the main menu press the B key Select a specific parameter to measure by pressing the corresp...

Страница 10: ...tation with channel 1 as the current channel pressing the 2 key will result in the handset displaying C SEL 2 In order to complete this channel selection theC key must be pressed Now the handset will...

Страница 11: ...play will show BRxxxxx where xxxxx is the current baud rate right justified in the 8 character display Numeric keys used to select the baud rates are given below Keys other than those identified below...

Страница 12: ...LBI 38599E APPENDIX A MASTR IIe UTILITY HANDSET OPERATION FOR STATIONS USING GROUP 5 OR EARLIER SOFTWARE A 1...

Страница 13: ...A 7 Potentiometer Adjust Mode A 7 Metering Mode A 8 Channel Select Mode A 9 Maintenance A 10 SPECIFICATIONS POWER SUPPLY Nominal 12 5 Vdc Range 10 to 16 Vdc No failure or lack of function within this...

Страница 14: ...udio input and output levels for the Control Shelf are controlled by electronic potentiometers These potentiometers must be also be adjusted by the Utility Handset and cable or by a personal computer...

Страница 15: ...display If an invalid function number is entered and either START or STOP is pressed the handset will display the INVALID key flag To make another selection from the Function Display Mode press the C...

Страница 16: ...le Start Enable the transmitter Stop Restore the original EEPROM setting Comment Since the Tx enable disable function is program mable both by channel and PTT type changing the channel or PTT may nega...

Страница 17: ...etting Comment See CG Encode Enable CG Decode Enable Start Enable channel guard decode Stop Restore the original EEPROM setting Comment See CG Encode Enable CG Decode Disable Start Disable channel gua...

Страница 18: ...function Aux Rx Disable Start Disable the auxiliary receiver and toggle Aux Rx Mute Stop No function Aux Control 1 On Start Activate Auxiliary 1 output Stop Restore the original EEPROM setting Aux Con...

Страница 19: ...onfigured MASTR IIe To enter the Metering Mode from the main menu press the B key Select a specific parameter to measure by pressing the corresponding number key as shown below Parameter MIIe function...

Страница 20: ...nt channel pressing the 2 key will result in the handset displaying C SEL 2 In order to complete this channel selection theC key must be pressed Now the handset will display CHAN 2 If desired adjustme...

Страница 21: ...dset 19A705965P1 or LBI 38412 for Utility Handset 19A705870P2 Circuit Analysis Test Specifications Handset Self Test Outline and Schematic Diagrams Parts List IC Data Ericsson Inc Private Radio System...

Отзывы: