Command Line Interface
If not present, the Near End sends an activation cell and waits for the
confirmation of the Far End to start continuity check exchange.
direction
Specifies the direction. It can be one of the following:
A-B
The Near End sends the CC cells but ignores any
CC cell received from the Far End.
B-A
The Near End does not send any CC cells but
collects the CC cells sent by the Far End.
Twoways
The Near End sends the CC cells and collects CC
cells received from the Far End. This is the default
value.
The second syntax is used to deactivate End-to-end continuity check.
forced
When present, it specifies to stop exchanging CC cells
without any deactivation preliminary exchange.
If not present, both ends exchange deactivation cells.
Twoways
When present, the Near End will refuse any continuity check
demand from the Far End.
If not present, the Near End will accept a continuity check
demand from the Far End.
Default
no oam-cont-check
Modes
ATM PVC configuration, ATM PVC Range configuration, VC
Class configuration, ATM VP configuration
Example
To activate end-to-end continuity check with
activation/deactivation preliminary exchange, in both
directions:
EXN400(config-vc-class)# oam-cont-check
twoways
2.9.3.16 oam-seg-cont-check
Description
Continuity check consists of sending Continuity Check cells
every second, and checking their arrival at the other end. Continuity check
can be activated in only one direction or both directions. This command is
used to configure segment continuity check.
This command is available only when OAM support is activated.
Syntax
oam-seg-cont-check [forced] [direction]
44
1553-LZY 214 2655 C 2004-11-24
Содержание EXN401
Страница 1: ...Users Guide EXN401 EXN410...
Страница 13: ...IntroductionContents Index 165 1553 LZY 214 2655 C 2004 11 24 xiii...
Страница 14: ......
Страница 95: ...Command Line Interface Default None Modes all 1553 LZY 214 2655 C 2004 11 24 81...
Страница 180: ...Ericsson AB Ericsson AB 2004 All Rights Reserved www ericsson com 1553 LZY 214 2655 C 2004 11 24...