2.10.3.4 range
pvc
Description
This command is used to configure a range of PVCs. After
running this command, the current mode becomes ATM PVC Range
Configuration mode.
Syntax
range range-name pvc [start-vpi/]start-vci
[end-vpi/]end-vci
or
[no]
range range-name
range-name
The name of the PVC range and the prefix for
each created PVC's name. It can be up to 8
alphanumeric characters long.
start_vpi/start_vci
Specifies the VPI and VCI for the first PVC. If
start_vpi/
is not specified, it defaults to 0.
end_vpi/end_vci
Specifies the VPI and VCI for the last PVC. If
end_vpi/
is not specified, it defaults to
start_vpi
.
range range-name
Modifies an existing PVC range definition
no range range-name
Removes PVC range definition
Default
No PVC range
Modes
ATM Interface configuration
Example
To create the range of PVC named
rgv0
with VPI 0 and VCI
ranging form 32 to 131:
EXN400(config-if-atm)# range rgv0 pvc 0/32
0/131
Example
To modify the range of PVC named
rgv0
:
EXN400(config-if-atm)# range rgv0
2.10.3.5 show
(local)
Description
This command displays the current configuration of the ATM
interface under configuration. It displays general configuration parameters
and the list of existing PVCs. The PVCs that have been defined within a
range are gathered into a single line describing the range. If one PVC of the
range has been changed, it is extracted from the range and is listed with
the single PVCs.
Syntax
show [pvc {name| [vpi/]vci}]
1553-LZY 214 2655 C 2004-11-24
53
Содержание EXN401
Страница 1: ...Users Guide EXN401 EXN410...
Страница 13: ...IntroductionContents Index 165 1553 LZY 214 2655 C 2004 11 24 xiii...
Страница 14: ......
Страница 95: ...Command Line Interface Default None Modes all 1553 LZY 214 2655 C 2004 11 24 81...
Страница 180: ...Ericsson AB Ericsson AB 2004 All Rights Reserved www ericsson com 1553 LZY 214 2655 C 2004 11 24...