background image

Technical data

40

8.4

LTU for DCT1800-S

8.4.1

LTU for DCT1800-S: CE marked version

Product number

: RTM/ROFNB 101 72/2

Compliance to European regulations and standards

CE marking

:

 

European Council Directives : 98/13/EC, Telecommunications Terminal 

Equipment and Satellite Earth Station 
Equipment

: 93/68/EEC, CE Marking Directive

PSTN attachment

: TBR21
: All applicable Advisory Notes of the 

Analogue Type Approval Advisory Board 
(dependent on sales area).

Compliance to non-European regulations and standards

Applicable standards dependent on sales area

Transmission performance

: ITU-T Recommendation G.712

8.4.2

LTU for DCT1800-S: non-CE marked version

Product number

: RTM/ROFNB 101 72/1

Compliance to non-European regulations and standards

Applicable standards dependent on sales area

Transmission performance

: ITU-T Recommendation G.712

0560

Содержание DCT1800-S

Страница 1: ...User s Guide DCT1800 S DECT Business Cordless Telephone System...

Страница 2: ......

Страница 3: ...User s Guide DCT1800 S...

Страница 4: ......

Страница 5: ...software for Windows optional To manage the cordless system a software package is optionally available called Cordless System Manager CSM for Windows1 This user s guide describesthebasicuseofCSM Forad...

Страница 6: ...change date and time on the cordless system how to make a backup of the cordless system and how CSM can help in case of troubles with the system Chapter 7 Preparing for remote maintenance How to conn...

Страница 7: ...5 2 5 Cable connections 15 2 6 Printer option 16 2 7 Cordless System Manager option 16 2 8 Accessories 16 Chapter 3 Switching the system on off 17 Chapter 4 Checking the system 19 4 1 Checking possibi...

Страница 8: ...orking with CSM 28 6 4 Replacing a cordless phone 29 6 5 Adding a cordless phone 29 6 6 Removing a cordless phone 30 6 7 Change system date and time 30 6 8 Troubleshooting with CSM 31 Chapter 7 Prepar...

Страница 9: ...Contents 9 Abbreviations and glossary 41 Index 43...

Страница 10: ...Contents 10...

Страница 11: ...with the cordless phones as with the fixed phones Once installed the DCT1800 S system requires no user actions unless the system is malfunctioning Further it may be desired to replace add or remove co...

Страница 12: ...roduce a short circuit that could cause fire electric shock or damage to the equipment Warning Follow the instructions in this user s guide precisely Performing other actions than described may cause...

Страница 13: ...he DCT1800 S system are Cordless phones Base stations Radio exchange Further options are Printer Cordless System Manager CSM for Windows a Windows based software package The system coverage is establi...

Страница 14: ...one Up to maximally 40 cordless phones are possible Any business cordless phone that is DECT GAP compliant can be used Preferably Ericsson DECT GAP compliant business cordless phones are used type DT2...

Страница 15: ...area the base station BS330 GAPwithinternalantennasandtheBS340 GAPwithexternalantennas are available Up to maximally 8 base stations can be used 2 4 Radio exchange The radio exchange enables data com...

Страница 16: ...move cordless phones Change date and time on the cordless system Examine the cordless system Generate and print service forms Initialise a modem for remote maintenance by a supplier If you leave these...

Страница 17: ...eoperationalthereisnoneedtoswitchthesystemoff Switchingthesystem off is only necessary if the system has problems After switching on the system must function properly within 90 seconds with no red LED...

Страница 18: ...Switching the system on off 18...

Страница 19: ...es anoverview ofthe LEDs at the bottomside ofthe radioexchange Fig 3 Radio exchange LEDs When the cordless system is operational LED1 must be on green indicating power on The other LEDs must be off Wh...

Страница 20: ...Off Red Message received but not read yet Read the message with CSM if available Note that the system may continue to function properly if only LED2 is on red 3 6 Off Red Radio exchange error Try res...

Страница 21: ...switching the radio exchange off waiting half a minute and switching it on again With CSM if available If the problem persists please contact your supplier Amber yellow brown Base station is OK but n...

Страница 22: ...Checking the system 22...

Страница 23: ...the next question Warning Do not try to solve faults a supplier has to solve incorrect actions may cause danger or damage the cordless system Follow the instructions given in this chapter precisely F...

Страница 24: ...CSM if available can give a detailed overview of the cordless system 5 2 System does not function at all 1 Is the green power LED1 on the radio exchange on See figure 3 page 19 Yes System is powered T...

Страница 25: ...OK now 3 Are all cables connected properly see figure 2 page 17 Yes Contact your supplier No Try connecting the cables If this does not help contact your supplier 5 4 Complaint of one user 1 Cordless...

Страница 26: ...any of LED3 LED6 remains on red contact your supplier No Contact your supplier 5 6 Date and time on cordless phone not correct Use CSM if available to set date and time on the cordless system Otherwis...

Страница 27: ...raph 6 7 Investigate the cordless system in case of troubles and generate and print service forms see paragraph 6 8 Initialise a modem for remote maintenance by a supplier see chapter 7 If you leave t...

Страница 28: ...and the windows For example if you want to subscribe a cordless phone first establish a connection then select the window Cordless Phones and finally choose the option Subscribe Cordless Phone from th...

Страница 29: ...backup in case of serious system troubles Note When the subscription has been cancelled you can subscribe another cordless phone to the same extension number 6 5 Adding a cordless phone The cordless s...

Страница 30: ...e Do not use the Delete Extension Number option to remove a cordless phone If an extension number is deleted the line connection between PABX and cordless system is terminated As a result it is not po...

Страница 31: ...inted or saved as a file These service forms are useful for your supplier in case of problems Reset system and unit With the Reset System option in the System menu the complete DCT1800 S system can be...

Страница 32: ...Using CSM 32...

Страница 33: ...side of the cordless system for remote maintenance of the cordless system Note In case of troubles with the modem see the accompanying documentation Initialising the system side modem with CSM 1 Dete...

Страница 34: ...change the AT commands that will be sent to the modem by clicking the Advanced button see the CSM help file 6 Disconnect the PC cable from the modem 7 Connect the modem to the cordless system with th...

Страница 35: ...or remote maintenance 35 3 If you use an external modem switch on the CSM side modem 4 Start CSM and choose from the Tools menu the option Manage Remote Systems Follow then the instructions of the CSM...

Страница 36: ...Preparing for remote maintenance 36...

Страница 37: ...300 329 EN 61000 3 2 EN 61000 3 3 Compliance to non European regulations and standards Applicable standards dependent on sales area Safety IEC 950 AS NZS 3260 ACATS001 Note The combination of radio e...

Страница 38: ...dem shell adapter RNTNB 102 109 Printer cable TSRNB 101 23 Power cable RPMNB 101 03 x CSM for Windows softw LZYNB 201 50 n 8 2 Base station BS330 GAP Product number KRCNB 301 xx n Compliance to Europe...

Страница 39: ...pecifications Powering method via 2 data pairs unshielded twisted pairs or 1 EPP depending on distance between base station and radio exchange Width x depth x height 200 x 165 x 56 mm incl mounting br...

Страница 40: ...ective PSTN attachment TBR21 All applicable Advisory Notes of the Analogue Type Approval Advisory Board dependent on sales area Compliance to non European regulations and standards Applicable standard...

Страница 41: ...ss Telecommunications Standard for cordless telecommunication GAP Generic Access Profile Communication protocol standard within DECT that guarantees compatibility of systems and components LED Light E...

Страница 42: ...Abbreviations and glossary 42...

Страница 43: ...S 11 access 11 base stations 15 building blocks 13 connection 11 cordless phones 13 15 CSM 27 options 13 printer 13 radio exchange 15 DECT 11 eavesdropping 11 environmental conditions base station 39...

Страница 44: ...e to set up a call 21 radio exchange 13 function 15 LEDs 19 removing a cordless phone 30 replacing a cordless phone 29 reset 24 with CSM 31 service form 31 switching on off 17 system expansion 11 tech...

Страница 45: ......

Страница 46: ...For further information please contact EN LZTNB 101 168 1 R2 1999 Subject to change without prior notice...

Отзывы: