Checking the system
21
LEDs on base station
LED1:
Green power LED (on when powered)
LED2:
Three colour LED, see table 2.
Status of LED2
Meaning
Required action
Off
Base station operational and
no
cordless phone is using the base
station
None
Green
Base station operational
and
a
cordless phone is using the base
station
None
Red
Base station is malfunctioning.
Try resetting the base station:
•
By switching the radio
exchange off, waiting half a
minute and switching it on
again.
•
With CSM (if available).
If the problem persists, please
contact your supplier.
Amber
(yellow-brown)
Base station is OK, but not avail-
able (self-test, not initialized, no
communication with radio
exchange)
Flashing green
8 cordless phones are currently
using the base station: the maxi-
mum capacity of the base station
has been reached
None
If this frequently happens while
users having problems setting up
a call, there may be not enough
base stations. Please contact
your supplier.
Table 2 Meaning of base station LED2
Содержание DCT1800-S
Страница 1: ...User s Guide DCT1800 S DECT Business Cordless Telephone System...
Страница 2: ......
Страница 3: ...User s Guide DCT1800 S...
Страница 4: ......
Страница 9: ...Contents 9 Abbreviations and glossary 41 Index 43...
Страница 10: ...Contents 10...
Страница 18: ...Switching the system on off 18...
Страница 22: ...Checking the system 22...
Страница 32: ...Using CSM 32...
Страница 36: ...Preparing for remote maintenance 36...
Страница 42: ...Abbreviations and glossary 42...
Страница 45: ......
Страница 46: ...For further information please contact EN LZTNB 101 168 1 R2 1999 Subject to change without prior notice...