Step 1—Select Location

Choose a proper place for the unit. In general, the best location is at the
center of the intended wireless coverage area, within line of sight of all wireless
devices. For optimum performance, consider these guidelines:

Mount the unit as high as possible above any obstructions in the coverage
area.

Avoid mounting next to or near building support columns or other
obstructions that can cause reduced signal or null zones in parts of the
coverage area.

Mount away from any signal absorbing or reflecting structures (such as
those containing metal).

The unit can be mounted on any wall or on a pole.

Warning!

Do not install the unit in any areas where blasting (blasting caps, radio
controlled equipment) or explosive gases can be present.

Warning!

To comply with FCC radio frequency (RF) exposure limits (FCC OET 65C) for
the general population, antennas must be located a minimum distance of 12
inches (approx. 30 cm) or more from the body of all persons.

6

1/006 92-LZA 101 803 Uen D

|

2013-12-13

Содержание AP 5113

Страница 1: ...BelAir20EO and AP 511x Series Quick Install Guide QUICK GUIDE 1 006 92 LZA 101 803 Uen D...

Страница 2: ...on shall have no liability for any error or damage of any kind resulting from the use of this document Trademark List Wi Fi Wi Fi is a registered trademark of the Wi Fi Alliance Wi Fi Certified Logo T...

Страница 3: ...as are ordered and shipped separately For AP 5115 to AP 5118 Customers supply their own power cable and use the power cable connector kit to terminate the cable Units can be powered either by AC power...

Страница 4: ...ower cable connector can damage the unit and voids the Ericsson product warranty 1 3 Internet Port and Power The unit can be powered with IEEE 802 3af or IEEE 802 3at Power over Ethernet PoE Use IEEE...

Страница 5: ...For streetlight or hydro telecom pole mounting the AC power adapter should be protected with a lightning surge protector AC power routed to the power adapter must be routed inside the pole If power is...

Страница 6: ...e unit When lightning arrestors are used they must be located within 3 feet approx 1 m of the unit and must be grounded to both the unit and protective earth ground The 1 4 GND screw of the unit can b...

Страница 7: ...r building support columns or other obstructions that can cause reduced signal or null zones in parts of the coverage area Mount away from any signal absorbing or reflecting structures such as those c...

Страница 8: ...ave the equivalent rigidity 1 Attach the mounting plate to the wall or pole For walls use up to four 1 4 inch M6 anchoring bolts Use the plate as a drill hole template The outer edges of the plate mus...

Страница 9: ...4 Attach unit to mounting plate a Insert mounting screws on the back of the unit into shoulder screw holes on mounting plate Slide unit down until screws are into the slots Tighten screws snug b Screw...

Страница 10: ...l Guide Note Ground wire not shown Small Pole Mounting Small poles have an outer diameter less than 3 inches 7 6 cms 1 Connect ground wire to unit 2 Use two stainless steel straps to secure unit to po...

Страница 11: ...11DR2 AP 5118R AP 5118U Two 2 4 GHz External 8 dBi 2 4 GHz 8 dBi Dual Feed Directional Antenna BNCKH0007 or INE 105 2159 AP 5113 One 2 4 GHz External 12 dBi Dual Polarization 2 4 2 5 GHz Flat Panel A...

Страница 12: ...connector Use thread locker and self amalgamating tape to keep connection tight and waterproof Connect external 5 GHz or 2 4 GHz antennas here Connect only antennas that are approved specifically for...

Страница 13: ...appropriate terminals by tightening screws on insert assembly 1 Refer to the following table Conductor Type North American Color European Color Terminal ID Ground Green Yellow Green Yellow 1 Power Bla...

Страница 14: ...nnected to a power source that complies to IEEE 802 3af or 802 3at Caution The PoE connection to the BelAir20EO and AP 511x series AP must use the supplied Ethernet gland to ensure a waterproof connec...

Страница 15: ...cators on the unit If the indicators are not as shown refer to the BelAir20EO and AP 511x Series Technical Description 1 1550 LZA 101 803 2 7 Step 7 Configure Unit In most cases the unit configures it...

Страница 16: ...any form without the written permission of the copyright owner The contents of this document are subject to revision without notice due to continued progress in methodology design and manufacturing Er...

Страница 17: ...BelAir20EO and AP 511x Series Conformity and Regulatory Statements STATEMENT OF COMPLIANCE 1 174 02 LZA 101 803 Uen C...

Страница 18: ...on shall have no liability for any error or damage of any kind resulting from the use of this document Trademark List Wi Fi Wi Fi is a registered trademark of the Wi Fi Alliance Wi Fi Certified Logo T...

Страница 19: ...4 Manufacturer s Industry Canada Conformity Statement 5 5 Manufacturer s European Community Conformity Statement 9 6 Declaration of Conformity for RF Exposure 12 7 Product Disposal 13 7 1 Mise au rebu...

Страница 20: ...BelAir20EO and AP 511x Series Conformity and Regulatory Statements 1 174 02 LZA 101 803 Uen C 2013 12 13...

Страница 21: ...document is intended for all personnel who want to learn more about the product 1 3 Comments About the Documentation Ericsson encourages you to provide feedback comments or suggestions so that we can...

Страница 22: ...terference to radio or television equipment caused by unauthorized modification of this device or attachment of any antennas or equipment other than those specified by the manufacturer The manufacture...

Страница 23: ...arantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipmen...

Страница 24: ...a minimum distance of 12 inches 30 cm between the radiator and your body This transmitter must not be colocated or operating in conjunction with any other antenna or transmitter Note The country code...

Страница 25: ...tennas having a higher gain is strictly prohibited per regulations of Industry Canada The required antenna impedance is 50 ohms Table 1 BelAir20EO and AP 511x series Antennas Type Gain Brand Manufactu...

Страница 26: ...ating antenna can be kept 30 cm from nearby person in normal operation condition to meet regulatory RF exposure requirement 3 External antenna Use only the antennas which have been approved by the app...

Страница 27: ...ricsson Ericsson Conform ment la r glementation d Industrie Canada le pr sent metteur radio peut fonctionner avec une antenne d un type et d un gain maximal ou inf rieur approuv pour l metteur par Ind...

Страница 28: ...d installation En usage normal afin de respecter les exigences r glementaires concernant l exposition aux radiofr quences ce produit doit tre install de fa on respecter une distance de 30 cm entre l a...

Страница 29: ...EC slenska essi b na ur samr mist l gbo num kr fum og rum kv um tilskipunar 1999 5 ESB Italiano Questo apparato conforme ai requisiti essenziali ed agli altri principi sanciti dalla Direttiva 1999 5 E...

Страница 30: ...rum Matters ERM Wideband Transmission systems Data transmission equipment operating in the 2 4 GHz ISM band and using spread spectrum modulation techniques Harmonized EN covering essential requirement...

Страница 31: ...ies AP Note This equipment is intended to be used in all EU and EFTA countries Outdoor use may be restricted to certain frequencies and or may require a license for operation for example in France the...

Страница 32: ...this Wireless LAN device is below the FCC radio frequency exposure limits However this device should still be installed and used in such a manner that the potential for human contact during normal op...

Страница 33: ...tenir un num ro d autorisation de retour du mat riel et des instructions sur les modalit s d exp dition 7 2 Produktentsorgung Ericsson erf llt die Anforderungen der Richtlinie 2002 96 EG des Europ isc...

Страница 34: ...rtskaffelse Ericsson overholder direktivet 2002 96 EC fra Europa Parlamentet og R det dateret den 27 januar 2003 om Waste Electrical and Electronic Equipment WEEE Affald af elektrisk og elektronisk ud...

Страница 35: ...equipo incluyendo las pilas contacte con el servicio de atenci n al cliente de Ericsson y obtenga el n mero de una Autorizaci n de Devoluci n de Material RMA y las instrucciones para la expedici n 15...

Отзывы: