INPUT 2 comes with a gain switch that selects between LINE level signals in the
input and MICROPHONE level signals (this setting is also recommended for guitar
pickups). Select the input amplifier gain and adjust the signal level with the LEVEL
knob. You can also overdrive the signal in the far clockwise settings of the level
controls. The INPUT 2 is DC coupled, which means it can also process control
voltages, and the DIRECT/INVERT switch inverts the incoming signal. This is
particularly handy, if you want to create patches with stereo panning.
See the patch example on the page 22 of this manual. INPUT 2 is also normalled
to the SCOPE OUTPUT, so, if nothing is patched into the INPUT 2 jack socket, a
signal from the SCOPE OUTPUT is automatically routed to INPUT 2.
The SCOPE is used to monitor both the CV and audio signal levels in the SYNTRX
II patches. The internal signal levels in the SYNTRX are line level, meaning, normal,
unattenuated audio signal that is about 3,7 Vptp, but it can be higher when several
signals are mixed; CV signals can be up to -5V - +5V .
Use the switch to select between CV and audio signal measurement. In the Audio
setting, the measurement starts from the left side of the scale and the full scale is
~4.5V. In the CV setting, the centre of the scale is 0 and it indicates both positive
and negative voltages.
The SCOPE has a dedicated SCOPE OUTPUT which you can use to get an extra
audio or CV signal.
INPUT 2
SCOPE
INPUT 2
LEVEL
LINE
MIC
INVERT
DIRECT
2
1
0
20
10
7 5
3
1
2
3
CV
AUDIO
13
Содержание SYNTRX II