Checking and Setting the Supply Voltage
On delivery, the unit is set for the local supply voltage (110/115 ~ or 230/240 V ~). The cur-
rent voltage setting is recorded on the mains module. The power unit covering lid on the bottom
of the unit must be opened to convert the voltage. The voltage can then be changed on the
power unit on-board with a special voltage selector switch.
Voltage conversion should only be performed by authorised and trained personnel.
8.6
Changing a Mains Fuse
The fuse switch is located in the centre of the mains module. The lid can be prised out of its
lock-in position with the help of a small screwdriver. It can then be pulled out of the fuse well.
Two fuses are located in the fuse switch. After a continuity check, change the fuses if necessary.
Return the fuse switch to the well and press it into the lock-in position.
Replace fuses only with other fuses of the same type with the same specification:
2 x 1.25 AT for 230 V, or 2 x 2.5 AT for 110 V.
8.7
Disposal information
Devices that are no longer usable can be returned to ergosana for disposal. Alternatively, the
device can be taken to an approved disposal location.
The control panel of the device contains a buffer battery, which must be disposed of separately.