25
BURNER TROUBLE SHOOTING
BURNER WILL NOT IGNITE
Step 1:
Check for 12 volts at “POWER” toggle switch.
No:
Engine key “OFF”
Toggle switch “OFF”
Blown fuse
Broken wire
YES:
12 volts at terminal #4 on “MATERIAL” Pak-Stat
NO:
Bad Pak-Stat
Faulty sensor
YES:
Check for 12 volts at terminal #7 on “OIL” Pak-Stat
NO:
Bad Pak-Stat
Faulty sensor
YES:
Check for 12 volts at solenoid (frame).
NO:
Bad solenoid
Bad connection at battery
Faulty circuit breaker
Broken or loose wire
YES:
Faulty DC Controller, poor ground / loose wire
Faulty or dirty flame
Faulty igniter transformer, cracked electrode
(ceramic)
Incorrect igniter gap
Faulty fuel solenoid
Bleed fuel pump / check fuel pump coupling
Fuse under DC Controller
Blower motor relay
Faulty blower motor
Faulty 12 volt battery
BURNER LIGHTS BUT SHUTS DOWN AFTER 15 SEC.
Faulty flame eye
Broken, loose flame eye sensor wires, receptacle
Faulty DC Controller
BURNER LIGHTS BUT WILL NOT RELIGHT
Bad connection at battery
Broken or loose wires
Faulty DC Controller
Faulty 12 volt battery
EXCESSIVE SMOKE FROM BURNER EXHAUST
Air vent incorrectly set - set at 7
Blower motor not turning at correct speed
Faulty 12 volt battery
Содержание Crafco Patcher I Diesel
Страница 1: ...Patcher I Diesel PART MANUAL 56933 Rev 0...
Страница 2: ...2 Revised 02 06...
Страница 3: ...3 Patcher I Diesel Part Number 56900 Skid Mount...
Страница 13: ...13 Fig 1 Fig 2 grease fitting safety chain discharge gate...
Страница 14: ...14 Fig 3 Fig 4 heat transfer dipstick mixer control switch...
Страница 15: ...15 Fig 5 temperature dials Fig 6 throttle lever toggle switch...
Страница 16: ...16 Fig 7 Fig 8 by pass valves engine fuel tank...
Страница 20: ...20 MAINTENANCE CHART...
Страница 28: ...28 Patcher I Diesel...
Страница 30: ...30 Patcher I Diesel...
Страница 33: ...33 Patcher I Diesel Notes...
Страница 34: ...34 Patcher I Diesel HYDRAULIC DIAGRAM...
Страница 35: ...35 Patcher I Diesel HYDRAULIC PARTS...
Страница 36: ...36 Patcher I Diesel HYDRAULIC PARTS...