17
SHUTDOWN PROCEDURE
1.
Turn burner toggle switch to “OFF.”
2.
Return mixer hydraulic control switch to “OFF” position.
3.
Turn off engine by closing stop lever and turn off key.
STORING MACHINE
The Patcher I Diesel should be stored in an area where moisture cannot enter machine.
Extended down time can cause moisture build up in heating oil tank.
If there is any suspicion moisture that may have collected in heat transfer oil, warm heat
transfer fluid to 300
O
F. for 2 to 3 hours to evaporate the moisture.
CAUTION
Extreme care must be used when operating this equipment. Safety is the result of being
careful and paying attention to details. Certain exposed parts of this machine, when operat-
ing, reach 500
O
F.; the material as high as 400
O
F. and the hydraulic fluid may reach 200
O
F.
Always
wear protective clothing and eye protection. Be sure that all joints and fittings are tight
and leakproof. Immediately replace any hose which show signs of wear, fraying or splitting.
Tighten all bolts, nuts and screws every 100 hours.
Содержание Crafco Patcher I Diesel
Страница 1: ...Patcher I Diesel PART MANUAL 56933 Rev 0...
Страница 2: ...2 Revised 02 06...
Страница 3: ...3 Patcher I Diesel Part Number 56900 Skid Mount...
Страница 13: ...13 Fig 1 Fig 2 grease fitting safety chain discharge gate...
Страница 14: ...14 Fig 3 Fig 4 heat transfer dipstick mixer control switch...
Страница 15: ...15 Fig 5 temperature dials Fig 6 throttle lever toggle switch...
Страница 16: ...16 Fig 7 Fig 8 by pass valves engine fuel tank...
Страница 20: ...20 MAINTENANCE CHART...
Страница 28: ...28 Patcher I Diesel...
Страница 30: ...30 Patcher I Diesel...
Страница 33: ...33 Patcher I Diesel Notes...
Страница 34: ...34 Patcher I Diesel HYDRAULIC DIAGRAM...
Страница 35: ...35 Patcher I Diesel HYDRAULIC PARTS...
Страница 36: ...36 Patcher I Diesel HYDRAULIC PARTS...