6 Operation

6.9  Settings

Some of the device settings are configurable to meet spe‑
cific requirements. The settings will be saved and remain 
stored even when the ergometer is switched off.

Use the softkeys on the right and left (

 

) to position the 

bar cursor on 

Settings

 and confirm the selection with 

Select

The configuration menu displays.

When all changes have been made, you can exit the config‑
uration menu with the 

 key.

 

 

PC Mode

  Ergometry

  Manual

 

Settings

Select

Figure 6 – 17:  Main menu

Use the softkeys on the right and left (

 

) to position the 

bar cursor on the parameter to change and confirm the 
selection with 

Select

.

 

Settings

  Default Mode

 Protocols

 Contrast

  Load Change

 Language

Select

Figure 6 – 18:  Settings menu

6.9.1  Default Mode

In this menu you choose the default mode activated when 
the ergometer is turned on. When first turned on after 
delivery, the ergometer will display this menu.

Use the softkeys on the right and left (

 

) to position the 

bar cursor on your preferred default mode and save the 
selection with 

Select

.

 

Default Mode

 Menu

  PC Mode

 Ergometry

 Manual

Select

Figure 6 – 19:  Selecting the default mode

6.9.2  Protocols

Protocols 6 to 15 are user‑programmable (protocols 1 to 5 
are fixed, see Appendix for protocol parameter details). 
Default values can be entered for the following parameters:

—  Basic Load
—  Stage Time
—  Load Stage (load increase with each stage)

Use the softkeys on the right and left (

 

) to position the 

bar cursor on the protocol to change  (No. 6 to 15) and 
confirm the selection with 

Select

.

 

Protocols

  1. WHO

  2. BAL

  3. Hollmann

  4. STD. France

  5. Standard

Select

Figure 6 – 20:   Selecting the exercise test protocol to edit

Содержание ergoselect 1

Страница 1: ...ergoselect 1 Bicycle Ergometer Operator s Manual 201000551000 Version 2021 05 12 Rev 02 English...

Страница 2: ......

Страница 3: ...n is acknowledged No part of this manual may be reprinted translated or reproduced without the manufacturer s written permission This manual will not be automatically updated Please contact the manufa...

Страница 4: ...2 ergoselect 1...

Страница 5: ...Indicators 12 5 2 Mounting the Control Terminal 12 5 3 Transport 13 5 4 Setup 13 5 5 Connecting the Power Cord 14 5 6 Connecting the ECG Cable 15 6 Operation 16 6 1 Turning the System On 16 6 2 Operat...

Страница 6: ...e 27 9 2 Technical Safety Inspections Inspections of the Measuring System 27 9 3 Disposal 27 10 Technical Specifications 28 10 1 Ergometer 28 10 2 Exercise Test Protocols 29 10 3 Family of characteris...

Страница 7: ...he device All device users and persons responsible for assembly maintenance inspection and repair of the device must read and understand the content of this manual before using the device or working w...

Страница 8: ...s may not be used in the immediate vicinity of the ergometer because they might interfere with the proper functioning of the ergometer Electromagnetic interference most probably exists when the watt r...

Страница 9: ...the device dizziness nausea or pain patients under the influence of substances that may impair vigilance alcohol drugs medication Contraindications in exercise testing carried out with ergometers sour...

Страница 10: ...ed specialists The group of intended users does not include persons whose mental and physical capabilities and skills have an adverse effect on their ability to use the medical device in accordance wi...

Страница 11: ...ion e g March 2020 Toggle switch ON voltage Toggle switch OFF voltage CE mark per the Medical Device Directive 93 42 EEC of the European Union Notified body T V S D Product Service GmbH Ridlerstr 65 8...

Страница 12: ...ing firmly check that the handlebar is tight by trying to push the handlebar downwards from above Adjust the clamping force of the rotary lever if necessary The handlebar is not designed to support th...

Страница 13: ...by turning it clockwise Figure 4 3 Tightening the rotary lever Warning Do not choose saddle height settings above the max mark Do not exceed the maximum height marked on the scale to avoid any risk of...

Страница 14: ...st the ergometer to uneven floors 8 Sockets for power cord and connection cables under side of ergometer Figure 5 1 Operating controls of the ergoselect 1 5 2 Mounting the Control Terminal The control...

Страница 15: ...t the ergoselect 1 When you have reached the new location lower the ergoselect 1 very carefully to protect it from considerable damage Caution Equipment Damage Avoid strong vibrations of the ergoselec...

Страница 16: ...the handlebar Plug the power cord into a wall outlet Figure 5 6 Power cord in strain relief mounted to frame Warning Arrange the power cord properly Lay the power cord flat on the floor Keep the powe...

Страница 17: ...ed into the 9 pole socket of the connection panel Port 1 or the USB port and secured at the metal frame with an additional strain relief Figure 5 7 Connection for ECG recorder PC ECG system 1 USB PC c...

Страница 18: ...Selftest running Figure 6 2 Self test screen Note Instructthepatientnottopedalwhiletheergometer is being turned on and during the self test The device can be configured to default to one of the operat...

Страница 19: ...n automatic exercise test some of the corresponding test protocols are user configurable and stored in the system see chapter 10 2 Exercise Test Protocols on page 29 Manual The ergometer is controlled...

Страница 20: ...ter receives commands from the controlling ECG unit or PC the exercise test will start and the corresponding values will be displayed The exercise test can only be terminated with the corre sponding c...

Страница 21: ...the display after approx 15 seconds and the patient s RPM indicator blinks the patient should start pedalling 0 0 Watt min sec min Start Figure 6 11 Starting the exercise test The internal protocol w...

Страница 22: ...tarted with the Start key afterwards the load can be set and changed with the 10 W and 10 W keys in increments of 1 W 5 W 10 W or 25 W as configured 0 0 Watt min sec min Start Figure 6 15 Initial scre...

Страница 23: ...s menu 6 9 1 Default Mode In this menu you choose the default mode activated when the ergometer is turned on When first turned on after delivery the ergometer will display this menu Use the softkeys o...

Страница 24: ...e the new value The other parameters are edited in the same way You exit the configuration with Protocol 6 Select Step Basic Load 20 W Stage Time min Load Stage W Select Figure 6 22 Editing the parame...

Страница 25: ...ental change of this setting the menu is protected with a password Enter the service code 003 and confirm with Select Select ECG Type Service Code 003 Figure 6 27 Entering the EKG Type password The er...

Страница 26: ...in Max 50 130 65 min Select Figure 6 29 Setting the RPM limit values 6 9 9 HR Belt Number If the test subject wears a chest strap to measure the heart rate during the training the corresponding chest...

Страница 27: ...s adjustable Ergonomics optional erg705 942 Pedal cranks adjustable w o tools Ergonomics optional erg705 786 Pedal extra wide with Comfort pedal straps set Pedal optional erg705 300 Tilt protection St...

Страница 28: ...isinfection and General Hygiene Measures The document Cleaning and Disinfecting ergoline Medical Devices Part No 201000641000 in its most recent version is also part of this manual This document is ex...

Страница 29: ...the measuring system must be completed every two years according to the rules of the art by a Service Engineer authorized by ergoline GmbH The date of the next inspection is indicated on the inspec t...

Страница 30: ...ols Control Terminal P 5 predefined incremental protocols WHO Hollmann etc 10 user programmable exercise test protocols Permitted patient weight 160 kg max Permitted patient height approx 120 210 cm c...

Страница 31: ...nment operation temperature 10 to 40 C rel humidity 30 to 75 no condensation atmospheric pressure 800 to 1060 hPa transport and storage temperature 20 to 70 C rel humidity 10 to 95 no condensation atm...

Страница 32: ...20 20 20 20 20 20 20 20 20 20 20 20 20 20 35 min 10 35 min 10 35 min 10 20 50 min 20 50 min 20 50 min 70 min 40 min 20 70 min 20 70 min 30min 10 30 min 10 30 min 10 30 min 10 30 min 10 30 min 10 30 mi...

Страница 33: ...system should be tested to verify normal operation in the configuration in which it is being used Guidance and Manufacturer s Declaration Electromagnetic Emissions Theergoselect1ergometerisintendedfor...

Страница 34: ...be that of a typical commercial or hospital environment Surge to EN 61000 4 5 1 kV differential mode 2 kV common mode 1 kV N A Mains power should be that of a typical commercial or hospital environme...

Страница 35: ...distance in meters m Field strengths from fixed RF transmit ters as determined by an electromag netic site surveya should be less than the compliance level in each frequency rangeb Interference may o...

Страница 36: ...power of the communications equipment Rated Maximum Output Power of Transmitter W Separation Distance according to Frequency of Transmitter m 150 kHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 M...

Страница 37: ......

Страница 38: ...ergoline GmbH Lindenstra e 5 72475 Bitz Germany Tel 49 0 7431 98 94 0 Fax 49 0 7431 98 94 128 e mail info ergoline com http www ergoline com...

Отзывы: