MI_STAR_EN.doc
SR Installation Manual EN
Indice : C
03/05/2019
14 / 15
ERECA SAS 75 rue d'Orgemont, 95210 SAINT GRATIEN France
Tel +33 1 39 89 76 23 www.ereca.fr
Powering
Consumption:
20 Watts per side
Low voltage source:
8 to 20 VDC, XLR 4 pins connector, protected by 5*20 mm standard internal fuse
Mains source:
From 90 to 260 VAC / 47 to 63 Hz
Dual supplies in the 1U rack
Mechanical
Rugged model:
Die cast strong aluminum case, size 335 x 235 x 111mm excluding connectors and handles
Rack model:
1 RU 19” rack, depth 300mm excluding connectors.
Cooling:
Internal fan / (Case walls acting as Heat sink / No dust entry guarantee for the RUGGED )
Operating Temp range:
From -20 to + 60°C. (Avoiding direct sun exposition)
Signaling / Setup
Transmitted signals:
1 LED per signal
Alarms
1 LED per technical alarm (Power supply / Temperature / Fiber alarm )
Remote
All signal presence / alarm are reported trough the web server.
Settings
All settings are done trough the web server.
Optical OPTION
Redundant path:
Double optical transmission with automatic optical path selection.
Optical losses:
1.8 dB per link for optical switching
Analog Audio OPTION
Input:
Microphone input gain block on 8 of the 16 channels
Mic input, Gain:
From 10 to 60 dB, Bypass and Tunable by 3 dB steps, through internal Web Server.
Phantom power:
48 volts switchable , through internal Web Server, Source Impedance 6.8 KΩ
Data OPTION
Number, connector:
12 bidirectional channels, one SUB D 25 for 6 channels (1U rack version).
Protocols:
RS422
Data rate:
0 to 19.2 Kbd/s
Remote Powering OPTION on LEMO 3K
Power topology:
Power source: 1U rack STAGE RACER
Powered device: Rugged STAGE RACER box
Camera powering:
12VDC, 30 W available on XLR 4
Performance with
AWG16 SMPTE cable:
2.5 km for rugged STAGE RACER box alone (no camera remote powered)
950 m for rugged STAGE RACER box + 30W camera load
Nota: Due to space limitation on the rugged box connector area; please contact ERECA Company for your application.