3.4.4
Consumptions of the GenPro 425e
Table 10 : Power supply range
Power supply range
7.2 V
DC
to 32V
DC
(8 V
DC
to 32V
DC
with battery option)
Table 11 : Consumption in shutdown mode @25 °C without battery charge
Shutdown Mode
I
Unit.
V
IN
7.2
12
24
32
V
I
2.6
2
1.2
1
mA
The
GenPro 425e
is attached to network
Table 12 : Consumption with attached mode @ 25 °C without battery charge
Attached mode
I
MOY MAX.
Unit.
V
IN
7.2
12
24
32
V
GSM / GPRS
@ DRX = 5
63
35
15
10
mA
UMTS
@ P=23dBm
64
35
17
12
mA
4G-LTE
75
40
19
15
mA
The
GenPro 425e
is attached to network
Table 13 : Maximum consumption with data transfer mode @ 25 °C without battery charge
Unit
V
IN
7.2
12
24
32
V
2G
Peak current
2 000
1000
460
350
mA
Average
280
140
80
65
mA
3G
Maximum
430
250
125
95
mA
Average
310
175
95
75
mA
LTE
Maximum
490
280
140
105
mA
Average
365
215
100
80
mA
Table 14 : Consumption of battery charge @ 25 °C
Battery charge
IMOY MAX.
Unit.
V
IN
8
12
24
32
V
175
115
60
40