5.1.3.2 Standard with EGM Library
The GenPro 2xe contains the EGM standard library; it is waiting for a command.
Connect the link RS232 between the DTE (COM port) and the modem (DCE).
Set the RS232 port of the DTE as follows:
▪
Bits per second:
115 200 bps
,
▪
Data Bits:
8
,
▪
Parity :
None
,
▪
Stop Bits:
1
,
▪
Flow control :
material.
Use a communication software like HyperTerminal ® of Windows.
Send the AT command. The modem returns OK. For more precision about the commands, see the
documents "EG_EGM_CL_xxx_yy" of ERCO & GENER.
With this status, the led is off.
In the case where no communication can be established with the modem:
▪
Check the RS232 connection between the DTE and the modem (DCE),
▪
Check the configuration of the COM port of the DTE.
5.1.3.3 The application ERCO & GENER EasePro-01
This application is being developed. Contact us.
5.1.3.4 The owner application
The GenPro 2xe contains your application.
Connect the RS232 link between the DTE (the COM port) and the modem (DCE).
Set the RS232 port of the DTE according to your parameters (speed, data bits, parity and stop bit).
Use a communication software like HyperTerminal ® of Windows.
Check the display and the dialogue with the GenPro 2xe according to your our characteristics.