ERBAUER 457MM SCROLL SAW ERB704SSW
Green & Yellow E(Earht)
Blue
(neutral)
N
5amp fuse
approved to
BS1362
Brown
(live)
L
Cable grip
Outer sleeve
5amp
PLUG REPLACEMENT (Fig. 21)
If you need to replace the fitted plug then follow
the instructions below.
IMPORTANT:
The wires in the mains lead
are coloured in accordance with the following
code:
Blue – Neutral
Brown – Live
Green/Yellow – Earth
As the colours of the wires in the mains lead
of this appliance may not correspond with the
coloured markings identifying the terminals in
your plug, proceed as follows. The wire, which is
coloured blue, must be connected to the terminal
which is marked with an N or coloured black. The
wire, which is coloured brown, must be connected
to the terminal which is marked with an L or
coloured red. The wire, which is coloured green/
yellow, must be connected to the remaining
terminal which is marked with an E or .
WARNING:
Never connect live or neutral
wires to the earth terminal of the plug. Only
fit an approved 5 Amp BS1363/A plug and the
correct rated fuse.
NOTE:
If a moulded plug is fitted and has to
be removed take great care in disposing of
the plug and severed cable, it must be destroyed
to prevent engaging into a socket.
replace if necessary. Replace both brushes even if
only one is damaged.
NOTE:
After inspecting the brushes, be sure
to re-install the brushes into the same
position that they were in if you are not installing
new ones.
- Position the brushes in the motor. Tighten the
brush caps snugly. Do not overtighten.
- Run the saw for approximately five to ten minutes
to allow the brushes to "seat" themselves. If the
brushes are not seated correctly, the electric brake
may not function correctly and could damage the
motor. While the brushes are seating, some
sparking may be noticed in the motor. This is
normal for new brushes.