background image

6Kg SDS HAMMER DRILL

SYMBOLS

            Read the manual   

Warning 

 

Wear gloves

            
            Wear dust mask,eye & ear protection 

 

            Conforms to relevant safety standards      

Important note

Be sure the supply is the same as the voltage given on the rating plate. The tool is fitted 

with a two-core cable and plug.

Remove the mains plug from socket before carrying out any adjustment or servicing.

Torque limiter 

There is a clutch in your hammer drill.

The torque limiter will actuate when a certain torque level is reached. The motor will 

disengage from the output shaft. When this happens, the bit will stop turning.

As soon as the torque limiter actuates, release the trigger and remove the tool and bit 

immediately. This will help prevent premature wear of the tool.

PDH130B ERB015SDS-M-070611.indd   7

2007-6-13   15:46:24

Содержание ERB015SDS

Страница 1: ...6Kg SDS HAMMER DRILL ERB015SDS WARRANTY YEARS PDH130B ERB015SDS M 070611 indd 1 2007 6 13 15 46 23...

Страница 2: ...es caused by the jamming by securely holding the drill with BOTH HANDS As this is a very powerful drill these forces are signi cant 2 ALWAYS ensure that the front handle is rmly af xed and secure 3 Th...

Страница 3: ...e maintenance Failure of consumable items such as batteries Accidental damage Cosmetic damage Failure to follow manufacturer s guidelines Loss of use of the goods Repairs attempted by anyone unless au...

Страница 4: ...ctric shock d Do not abuse the cord Never use the cord for carrying pulling or unplugging the power tool Keep cord away from heat oil sharp edges or moving parts Damaged or entangled cords increase th...

Страница 5: ...e making any adjustments changing accessories or storing power tools Such preventive safety measures reduce the risk of starting the power tool accidentally d Store idle power tools out of the reach o...

Страница 6: ...y high torque machine should not be used while standing on a lad der 9 Before starting to work always check that the chisel or drill bit is properly locked in the chuck 10 Hold the tool rmly with both...

Страница 7: ...ns plug from socket before carrying out any adjustment or servicing Torque limiter There is a clutch in your hammer drill The torque limiter will actuate when a certain torque level is reached The mot...

Страница 8: ...OFF SWITCH 5 HAMMER OR DRILLING ACTION SELECTOR SWITCH 6 VARIABLE SPEED CONTROL 7 AUXILIARY HANDLE 8 SDS DRILL BITS 9 DUST COVER 10 CARBON BRUSH 11 GREASE TANK 12 DEPTH GAUGE 13 CHISELS POINT AND FLAT...

Страница 9: ...mm Drill capacity in masonry 32mm Protection class II Net weight 5 7kg NOISE AND VIBRATION DATA Sound pressure level 92dB Sound power level 105dB Vibration level 14 9m s2 ACCESSORIES Auxiliary handle...

Страница 10: ...felt the shaft drops completely into bit holder Once you are satis ed it has seated release the black lock sleeve This should lock the SDS tool into position After installing always make sure that the...

Страница 11: ...er a little then adjust the selector switch again 2 Turn the hammer or drilling action selector switch pointing to the hammer action position See Fig 6 3 You are now set up for hammer drilling into ma...

Страница 12: ...g the depth gauge See Fig 11 The depth gauge can be used to set a constant depth to drill To use the depth gauge loosen the handle by rotating the bottom section of handle anti clockwise Insert the de...

Страница 13: ...nder 6mm When brushes need replacement always renew both brushes even if one is still more than 6mm long Completely screw down the carbon brush cap Check that the tool is working Before use allow it r...

Страница 14: ...mer does not start check the plug on the mains supply rst 2 If your hammer becomes too hot in use set the hammer switch to the drill mode and allow your drill to operate at maximum speed without load...

Страница 15: ...ire which is coloured blue must be connected to the terminal which is marked with N The wire which is coloured brown must be connected to the terminal which is marked with L Warning Never connect live...

Страница 16: ...000 14 EC amended by 2005 88 EEC Conformity Assessment Procedure as per Annex VI Measured Sound Power Level 104 dB Declared Guaranteed Sound Power Level 105dB The noti ed body involved Name TUV Rheinl...

Страница 17: ...PDH130B ERB015SDS M 070611 indd 17 2007 6 13 15 46 27...

Страница 18: ...PDH130B ERB015SDS M 070611 indd 18 2007 6 13 15 46 27...

Страница 19: ...PDH130B ERB015SDS M 070611 indd 19 2007 6 13 15 46 27...

Страница 20: ...PDH130B ERB015SDS M 070611 indd 20 2007 6 13 15 46 27...

Отзывы: