RECESSED, CLOSET AND ALCOVE INSTALLATION
13
The installation spacing is in inches and is the minimum acceptable.
Other installations must use the minimum dimension indicated.
★
Additional clearances for wall, door and floor molding may be required.
★★
Additional space is needed when an external exhaust elbow is used.
NOTE:
If a door is installed that potentially encloses the unit while running, the door must
allow for a minimum of 20 square inches of free air movement. There must also be a 1”
space in front of the unit to the closed door and 1” from the back of the unit to the wall.
Additional spacing should be considered for easy installation, servicing and compliance with
applicable local, state, and federal codes.
For
Venting Use
, see Fig 9,
For
Condensing Use
, see Fig 10.
et and adjacent walls are: 2″ either side and 3″ front and rear.
imum of 60 sq. in. of open
lled in the same with closet with dryer.
Minimum clearances between dryer cabin
Minimum vertical space from floor to overhead cabinets, etc. is 52″ (132cm).
Closet door must be louvered or otherwise ventilated and must contain a min
area equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of
120 sq. in. of open area equally distributed.
No other fuel-burning appliance shall be insta
(
Fig.9
)
(
Fig.10
)
2
"
2
"
3
"
3
"
3
"
3
"
2
"
2
"