![eQ-3 Homematic HM-LC-Sw4-DR Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/eq-3/homematic-hm-lc-sw4-dr/homematic-hm-lc-sw4-dr_installation-and-operating-manual_2420418025.webp)
48
49
11 Response to power recovery
When the operating voltage is switched on (recovery of
mains voltage), the actuator checks its components . If
an error is detected, all channel LEDs will flash. This is
repeated continuously and the device does not perform
its function . If the test is completed without errors, the
actuator transmits a wireless telegram containing its
status information . To prevent all actuators from trans-
mitting at the same time when power is recovered (after
a mains power failure or a disconnection, for example),
there is a random delay before the actuator transmits .
During this time, the channel LEDs flash (as in teach-in
mode). If the delay is very short, this flashing may be
almost imperceptible .
12 Maintenance and cleaning
The product does not require any maintenance . Enlist
the help of an expert to carry out any repairs .
Disconnect the device from the power supply system
before commencing cleaning . Use a dry linen cloth to
clean the device . If the device is particularly dirty, you
can slightly dampen the cloth to clean it . Do not use any
detergents containing solvents for cleaning purposes .
Make sure that no moisture will ingress into the housing .
13 Technical data
Device short description: HM-LC-Sw4-DR
Supply voltage :
230 V/50 Hz
Current consumption:
20 mA
Standby power consumption: 0 .4 W
Outputs:
4 potential-free relay
switch outputs
Relay:
Shutter contact
Kind of load:
Ohmic load
Switching capacity (max .): 3680 W
(230 V/50 Hz/16 A) per
channel, total for all chan-
nels max . 25 A (5750 W)
Cable type and cross section: rigid wire 0 .14-2 .5 mm²;
flexible wire, with ferrule,
0 .14–1 .5 mm²
Installation:
mounting rail (DIN rail)
according to EN50022
Radio frequency:
868 .3 MHz
Receiver category:
SRD Class 2
Typ . open area RF range: > 100 m
Duty cycle:
< 1 % pro h
Degree of protection:
IP20
Protection class:
II
Ambient temperature:
-10 °C to +55 °C