62
63
8. Adapter run
Once the batteries have been inserted, the motor rever-
ses; meanwhile, “InS” and the activity symbol ( ) are di-
splayed. As soon as “InS” is displayed without the activity
symbol ( ), the MAX! Radiator The can be moun-
ted. This is followed by an adapter run (“AdA”) to adapt the
thermostat to the valve.
•
Attach the radiator thermostat to the valve.
•
Tighten the union nut.
•
Press the boost button when “InS” is displayed.
The actuator performs an adapter run. “AdA” and the activity
symbol ( ) are displayed; during this time, operation is
not possible.
If the adapter run has been initiated prior to mounting or if
an error message (F1, F2, F3) is displayed, press the Boost
button; the motor reverses to the “InS” position.
If the MAX! Radiator The has not been
taught-in to the MAX! Cube, the device automatic-
ally switches to manual operation (Manu).
Teach-in mode can be activated also while “InS” is
displayed.
9. Teach-in
In order to enable use of the MAX! Radiator The
in your installation, the device has the be taught-in first.
The teach-in procedure depends on the system variant
used (House Solution, Room Solution or Radiator Solu-
tion). Choose your system variant and follow the instruc-
tions below.
MAX! House Solution
In the MAX! House Solution all settings and pro-
grammings (e.g. week programmes) can be made
via the
MAX! software
.
•
First activate the teach-in mode of the MAX! Cube. Please
start the local MAX! software and click on „New device“.
•
Now activate teach-in mode on the MAX! radiator thermo-
stat+. Press and hold down the Boost button for at least
3 seconds. The teach-in time remaining in seconds is
displayed. The teach-in time is 30 seconds.
•
If teach-in has been successful, the display returns to
normal display.
1.
2.
> 3 Sec.