Epygi Technologies
Configuring Quadro with ISDN
Please Note:
This route is only needed if the device has the second ISDN Trunk
available.
•
Route 3:
-
enter 9\*3* into Pattern text field, choose ISDN from Call Type
drop down list,
-
select ISDN Trunk2 from Port ID drop down list,
-
insert {11-26} into the Inbound Caller Pattern text field and
56834 in the Inbound Prefix text field. Choose PBX from Inbound
Call Type drop down list.
With this route, extensions from 11 to 26 will be able to make outgoing
ISDN calls selectively by the ISDN Trunk2. The caller’s information sent to
the ISDN CO, will be 56834xx, where xx is the particular extension’s
number (from 11 to 26).
Please Note:
This route is only needed if the device has the third ISDN Trunk
available.
•
Route 5:
-
enter 9* into Pattern text field, choose ISDN from Call Type drop
down list,
-
select Any Port from Port ID drop down list,
-
insert * into the Inbound Caller Pattern text field, insert 99 in
Inbound Number of Discarded Symbols (just a symbolic large
number to remove all Inbound Caller Pattern) and enter 5554645 in
the Inbound Prefix text field.
With this route, all extensions will be able to make outgoing ISDN calls
selectively by the first available ISDN Trunk. The caller’s information sent
to the ISDN CO for all extensions will be 5554645 (this is one of the numbers
provided by ISDN provider. Some ISDN providers request the caller ID to match
the number registered in the ISDN provider’s database, otherwise the call might
be rejected).
•
Route 6:
-
enter 56834{11-26} into Pattern text field, insert 5 in the
Number of Discarded Symbols, choose PBX from Call Type drop
down list,
-
insert * into the Inbound Caller Pattern text field and choose ISDN
in the Inbound Call Type drop down list.
With this route, all incoming calls from PSTN addressed to the ISDN
numbers in a range from 5683411 to 5683426 will be routed to the PBX
extensions 11 to 26 correspondingly.
•
Route 7:
-
enter 555464[5-9] into Pattern text field, insert 4 in the Number
of Discarded Symbols and 11 into Prefix text field, choose SIP
from Call Type drop down list,
-
insert * into the Inbound Caller Pattern text field and choose ISDN
in the Inbound Call Type drop down list.
With this route, all incoming calls from PSTN addressed to the ISDN
numbers in a range from 5554645 to 5554649 will be routed to the
sip.epygi.com SIP server with the usernames 11645 to 11649
correspondingly.
Please Note:
This route is only needed if incoming calls are ought to be
n SIP server.
redirected to the certai
PAGE 15