19. MAINTENANCE
WARNING!
Any work carried out on the appliance by the user strictly requires the power
plug being disconnected from the mains socket.
ATTENTION!
Use protective shoes and gloves during maintenance operations.
OPERATION
FREQUENCY
ORDINARY /
EXTRAORDINARY
MAINTENANCE
AUTHORISED
STAFF
Static condenser cleaning
Monthly
Ordinary
User
Cleaning the outer surface
Based on use
Ordinary
User
Cleaning the accessible inner parts
(do not use tools)
Based on use
Ordinary
User
Checking the power supply, electrical plugs and/or sockets
Six-monthly
Ordinary
User
Seals intactness check
Six-monthly
Ordinary
User
Check the acceptable condition of warning plates
Six-monthly
Ordinary
User
Fridge system tubing intactness check
Six-monthly
Ordinary
Technical support
Inspecting the cables and inner power connections
Six-monthly
Ordinary
Technical support
Replacing the led lights
-
Extraordinary
Technical support
Replacing the power supply cable
-
Extraordinary
Technical support
Control panel replacement (electronic control unit)
-
Extraordinary
Technical support
The equipment manager is obliged to check and comply with the maintenance deadlines in the
table indicated below.
Any other maintenance operation not planned in the previous points should be
carried out by the support centres authorised by our dealers or by qualified staff.
20. TEMPERATURE SETTING AND CONTROLS
Each refrigerating appliance is provided with an electronic control for automatic maintenance of the
appropriate pre-established temperature inside the tank.
This temperature adjuster is gauged by the factory and should not be touched by the user.
Only if the average internal temperature is too cold or not cold you can increment or decrement
the temperature:
1.
Unlock
the electronic controller by hold down “SET” button for 5 sec. (on the display the word
“UNLOCK” will appear).
1. Press the (SET)
key
in order to see on display the temperature set point.
2. Press the (
▲
) key or the (
▼
) key
in order to increment or decrement the temperature set point.
3.
Press the (SET) key
in order to store the
new
temperature set point.
LIGHT SWITCH
(Short pressure)