2-4
Installation Rev.
B
Confidential
Customer Display Connection Setting
There are two types of TM printers: One type has a DM-D connector (a connector for the
customer display) and the other type does not have a DM-D connector. The customer display
settings for each type are as follows:
TM Printer with No DM-D Connector
The cable for the customer display is connected to the DM-D connector on the UB-S09 and the
customer display connection is set using the jumpers on the UB-S09.
Note:
•
DM-D connection is selected from JP1; however if no DM-D is actually connected to the connector of the
UB-S09, the RTS signal will always be BUSY.
•
Operations are based on these JP1 settings even if the DM-D is not actually connected.
TM printer with a DM-D Connector
The customer display cable can be connected to either the connector on the UB-S09 or on the TM
printer; however, it is recommended to connect the cable to the connector on the TM printer.
The TM printer must be set to enable the DM-D connection by the DIP switch on the TM printer.
(For details, refer to the DIP switch section in the specification of each TM printer.)
Table 2-3 Customer display connection settings and operations 1
UB-S09 connector
Operation
DM-D not connected
(JP1: 2-3 shorted)
•
ESC=
default of TM printer: Printer select
•
Self test print: No DM-D settings print
•
GS I
: No DM-D DIP switch status function
•
RTS signal: No DM-D status output
DM-D connected
(JP1: 1-2 shorted)
•
ESC=
default of TM printer: Printer select
•
Self test print: No DM-D settings print
•
GS I
: No DM-D DIP switch status function
•
RTS signal: DM-D status output from UB-S09 connector
Содержание UB-S09
Страница 2: ...SEIKO EPSON CORPORATION Printed in Japan EPSON ...
Страница 8: ...vi Rev B Confidential ...
Страница 12: ...1 4 System Preparation Rev B Confidential ...
Страница 22: ...3 2 Operation Rev B Confidential ...
Страница 26: ...4 4 Function Description Rev B Confidential ...
Страница 28: ...Appendix A 2 Connector Terminal Signals Rev B Confidential ...