TM200 Service Manual
- 4 -
EMI and Safety Standards Applied
These standards are only valid for products which bear a mark or statement on the main unit.
Europe:
CE marking: Directive: 89/336/EEC
EN55022:1998 Class A
EN6100-3-3:1995+A1:2001
EN55024:1998, including
IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5,
IEC61000-4-6, IEC61000-4-8,
Safety standards:
EN60950
North America:
EMI:
FCC Class A
Safety standards:
UL1950/CSA C22.2 No.950
Oceania:
EMI:
AS/NZS3548
Conditions of acceptability
1. This component has been judged on the basis of the required spacing in the Standard
for Information Technology Equipment, including Electrical Business Equipment, UL
1950 and CSA22.2 No. 950. sub-clause 2.9, which would cover the component itself if
submitted for Listing.
2. The terminals and connectors have not been evaluated for field wiring.
Reliability
Life
:
Mechanism:
15,000,000 lines
Thermal head:
100 million pulses, 50 Km
Autocutter:
1,200,000 cuts
(End of life is defined to have been reached
when it reaches the beginning of the wear out
period.)
MTBF:
360,000 hours
(Failure is defined as a random failure
occurring during the time of the random
failure period.)
MCBF:
52,000,000 lines
(This is an average failure interval based on
failures relating to wear out and random
failures up to the life of 15 million lines.)
External Dimensions and Weight:
Height:
Approximately 138.7 mm (5.46")
Width:
Approximately 146.5 mm (5.77")
Depth:
Approximately 195 mm (7.68")
Weight:
Approximately 1.4 kg (3.08 lb)