TM200 Service Manual
- 11 -
DIP switch 1
Note:
TM200 accept ESC/POS command. Dip 1-1 for different printing format, ON(TM200)
for 48 characters per line, OFF(
EPSON Emulation) for 42 Characters per line.
Print Density Selection
DIP switch 2
DIP switch Function
ON
OFF
1-1 Print
emulation
TM200(default) EPSON
Emulation
1-2
Paper near end sensor
Vertical
Horizontal(default)
1-3
1-4
Selects print density
Refer to the table as below
1-5 Cutter
setting
Disable
Enable(default)
1-6
Stop bit
Fixed to OFF (1 bit)
1-7 Cutter
mode
Full
Partial(default)
1-8
Reserved: do not change
settings
Fixed to OFF
Print Density
SW 1-3
SW 1-4
1 Low power consumption
mode
ON ON
2 (Normal)
OFF(default)
OFF(default)
3 ON
OFF
4 (Dark)
OFF
ON
DIP switch Function
ON
OFF
2-1 Reserved
Reserved
2-2
Receive buffer capacity
2K bytes
96K bytes(default)
2-3
Handshaking
Fixed to OFF
2-4
Data word length
Fixed to OFF (8 bits)
2-5
Parity check
Fixed to OFF (None)
2-6 Parity
selection
Even
Odd(default)
2-7
2-8
Transmission speed (See the table below)