Operating Principles
Mechanism Operating Principles
2.2.9 Pressure Pump Mechanism
2.2.9.1 Pressure Pump Motor
Drive system
2.2.9.2 Pressure Sensor
Function: Detection of pressurization / pressure release
Detector specifications
Figure 2-29. Pressure Pump Assy Mechanism
Item
Specifications
Type
DC brush motor
Voltage
42 V (DC voltage) ±5% (voltage applied to the driver)
Basic
characteristics
Armature resistance
64.7
Ω
±15%
Inductance
37.6mH ±25%
Rotor inertia
3.97 gcm
2
Drive system
PWM system, constant-current chopping system
Operation
Current
Direction of Motor Rotation
(as viewed from the output side)
Pressure
OUT_A
→
OUT_B
CW
Pressure release
OUT_A
→
OUT_B
CCW
PWM driving
method
The PWM fundamental period resolution is 24 MHz (= 41.7 nsec), which is taken as
one count. The output time is the ON time, while the remaining time is OFF time.
During the OFF time in PWM driving mode, the slow-decay mode is used with both
the transistors on the sink side turned ON (synchronous rectification is enabled in the
active mode). Unless specified, the motor is stopped by a short brake (duty=0).
Current chopping
method
The slow-decay mode (chopping OFF time of 50
µ
sec.) is always used during
current chopping for current control. The slow-decay mode is such that the blanking
time is 6
µ
sec. and both the transistors on the sink side are turned ON during
chopping OFF in PWM driving mode. (Synchronous rectification is enabled in the
active mode.) The upper limit current value is ± 0.63[A] ± 8%.
Item
Specifications
Detection method
Photo-electric conversion system (transmissive-type photo-interrupter)
Model
GP2S24C J000F (SHARP)
Voltage
3.3 V ± 5%
Detected Condition
Detector Output
Remarks
Pressurized
H
Light transmitted
Pressure released
L
Light intercepted
Pump HP Sensor
Pressure Sensor
Pressure Pump Motor
Pressure Pump
Relief Valve
CW rotation
CCW rotation
The valve is closed, so
that the compressed
air is supplied through
the I/C Holder to the
Printhead.
When the gear turns
counterclockwise, the
lever pushes up the valve
to release the compressed
air from the chamber.
Содержание Stylus Photo RX700 Series
Страница 1: ...EPSON StylusPhotoRX700 Scanner Printer Copier SERVICE MANUAL ECOS SEMF05001 ...
Страница 9: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 17: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 51: ...C H A P T E R 3 TROUBLESHOOTING ...
Страница 64: ...EPSON Stylus Photo RX700 Revision A Troubleshooting Overview 64 Flowchart 3 2 Printing Processing ...
Страница 76: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Страница 133: ...C H A P T E R 5 ADJUSTMENT ...
Страница 146: ...C H A P T E R 6 MAINTENANCE ...
Страница 163: ...C H A P T E R 7 APPENDIX ...
Страница 175: ...Model PM A900 Stylus PHOTO RX700 Board C583Main Sheet 1 3 Rev H ...
Страница 176: ...Model PM A900 Stylus PHOTO RX700 Board C583Main Sheet 2 3 Rev H ...
Страница 177: ...Model PM A900 Stylus PHOTO RX700 Board C583Main Sheet 3 3 Rev H ...
Страница 178: ...Model PM A900 Stylus PHOTO RX700 Board C583 PNL PNL B Sheet 1 1 Rev C ...
Страница 179: ...Model PM A900 Stylus PHOTO RX700 Board C583PSB Sheet 1 1 Rev H ...
Страница 180: ...Model PM A900 Stylus PHOTO RX700 Board C583PSE Sheet 1 1 Rev F ...
Страница 185: ...For 220V 240V 401 400 03 02 01 100 Rev 01 C583 ACCE 001_Overseas PM A900 EPSON STYLUS RX700 NO 1 ...