Confidential
Adjustment
Details of Adjustments (TBD)
61
Epson Stylus Photo R3000
Revision A
7. Connect the calibrator to the PC and click [Color Measuring]. The color measurement procedure screen
operated by the Calibrator control plug-in (DLL) is displayed on screen overlapping the Colorimetric
Calibration Tool.
Figure 2-31. Color Measurement
8. Place the calibrator on the calibration plate, and click [Calibrate].
Figure 2-32. Preparing the Calibrator
The white reference tile on the calibration plate should be clean. Clean off any dirt with
alcohol or other organic solvent.
The calibration plate and the calibrator are used as a pair. Do not use a calibration plate
supplied with an another calibrator.