Epson Research and Development
Page 11
Vancouver Design Center
S5U13700B00C Rev. 1.0 Evaluation Board User Manual
S1D13700
Issue Date: 2005/07/15
X42A-G-002-01
Revision 1.0
JP2 - NIOVDD
JP2 can be used to measure the current consumption of the S1D13700 LCD panel interface.
When the jumper is at position 1-2, normal operation is selected.
When no jumper is installed, panel interface current consumption can be measured across
JP2.
Note
The NIOVDD voltage can be selected to be +3.3V or +5V using jumper JP8.
Figure 3-3: Configuration Jumper JP2 Location
Top View
JP2
Normal Operation
NIOVDD current
measurement