RX8010
SJ
Page
−
6
ETM37E-06
8.2.
AC characteristics
8.2.1. AC characteristics(1)
*
Unless otherwise specified, GND =
0
V
,
V
DD
=
1.6
V
∼
5.5
V
,
Ta
=
−
40
°
C
∼
+85
°
C
Item
Symbol
Standard-Mode
(f
SCL
=100kHz)
Fast-Mode
(f
SCL
=400kHz)
Unit
Min.
Max.
Min.
Max.
SCL clock frequency
f
SCL
100
400
kHz
Start condition setup time
t
SU;STA
4.7
0.6
µ
s
Start condition hold time
t
HD;STA
4.0
0.6
µ
s
Data setup time
t
SU;DAT
250
100
ns
Data hold time
t
HD;DAT
0
0
ns
Stop condition setup time
t
SU;STO
4.0
0.6
µ
s
Bus idle time between
start condition and stop condition
t
BUF
4.7
1.3
µ
s
Time when SCL =
"L"
t
LOW
4.7
1.3
µ
s
Time when SCL = "H"
t
HIGH
4.0
0.6
µ
s
Rise time for SCL and SDA
t
r
1.0
0.3
µ
s
Fall time for SCL and SDA
t
f
0.3
0.3
µ
s
Allowable spike time on bus
t
SP
50
50
ns
•
Timing chart
t
HD ; DAT
t
SU ; DAT
t
HD ; STA
t
LOW
t
HIGH
1 / f
SCL
t
r
t
f
t
SU ; STA
SDA
SCL
START
CONDITION
(S)
BIT 7
MSB
(A7)
BIT 6
(A6)
ACK
(A)
Protocol
t
BUF
t
SU ; STO
STOP
CONDITION
(P)
START
CONDITION
(S)
(P)
(A)
t
HD ; STA
t
SU ; STA
(S)
BIT 0
LSB
(R/W)
(S)
t
SP
Caution:
When communication of I
2
C-bus is started, consumption electric currents increase.
When accessing this device, all communication from transmitting the start condition to transmitting the stop
condition after access should be completed within 0.95 seconds.
If such communication requires 0.95 seconds or longer, the I
2
C bus interface is reset by the internal bus
timeout function.
8.2.2. AC characteristics (2)
*
Unless otherwise specified, GND =
0
V
,
V
DD
=
1.6
V
∼
5.5
V
,
Ta
=
−
40
°
C
∼
+85
°
C
Item
Symbol
Condition
Min.
Typ.
Max.
Unit
FOUT symmetry (/IRQ2)
SYM
50% V
DD Level
40
50
60
%