14. How to use
RX4111CE
Jump to
ETM62E-02
Seiko Epson Corporation
45
14.8.3. Time Stamp function triggered by SPI Access
1) COMTG bit (Command Trigger) Time stamp by SPI-Bus access.
Note: EVF is not set by SPI-Bus command trigger. Therefore, Time stamp interruption doesn
’
t occur.
This function was prepared for to read time data of sub seconds from Year without contradiction.
Table 54 COMTG bit (Command Trigger)
COMTG
Data
Description
Write
0
Time stamp by SPI-Bus is disabled.
1
Time stamp by SPI-Bus available
When a reading command to Bank2 address Fh is transmitted by SPI-Bus,
the time is recorded by Bank2 address 0h to 9h.
The read value of Bank2
address Fh is 0h.
2) Time stamp Timing
1
1
1
1
/INTpin
DI
CLK
Time stamp trigger
1
Trigger
Register data
Time stamp data
New Time stamp data
Mode + Address(Ah + Fh)
Dummy read
Figure 35 Time Stamp SPI-Bus record timing