EPSON Perfection 3200 Photo
Revision A
Disassembly and Assembly
DISASSEMBLY AND ASSEMBLY
40
7.
Remove the two screws (CBS, M3x5) and disengage the three hooks, and
then remove the main circuit board shield plate. (See Figure 4-14)
8.
Disconnect the white FFC from the main circuit board. (See Figure 4-15)
9.
Disconnect the white FFC from the ferrite core. (See Figure 4-15)
10. Disconnect the white FFC from the carriage unit. (See Figure 4-16)
Figure 4-14. Carriage Unit Removal (4)
Figure 4-15. Carriage Unit Removal (5)
Figure 4-16. Carriage Unit Removal (6)
The FFCs should be attached to the base frame with
double-sided tape.
CBS Screws (3x5)
Tightening Torque : 8-10kgfcm
Main Circuit Board
Shield Plate
Hooks
FFC
Main Circuit Board
Ferrite Core
FFC Connector
FFC
Carriage Unit
Содержание Perfection 3200 Photo
Страница 1: ...EPSON Perfection3200Photo Color Image Scanner SESC02 003 SERVICE MANUAL ...
Страница 5: ...Revision Status Revision Issued Date Description A November 18 2002 First Release ...
Страница 8: ...C H A P T E R 1 PRODUCT DESCRIPTION ...
Страница 21: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 29: ...C H A P T E R 3 TROUBLESHOOTING ...
Страница 36: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Страница 58: ...C H A P T E R 5 ADJUSTMENT ...
Страница 61: ...C H A P T E R 6 MAINTENANCE ...
Страница 64: ...C H A P T E R 7 APPENDIX ...
Страница 70: ......
Страница 71: ......
Страница 72: ......