Maintenance 8. Joint #4
116
LS10-B Rev.6
8. Joint #4
WARNING
■
Do not insert or pull out the motor connectors while the power to the robot system
is turned ON. Inserting or pulling out the motor connectors with the power ON is
extremely hazardous and may result in serious bodily injury as the Manipulator
may move abnormally, and also may result in electric shock and/or malfunction of
the robot system.
■
To shut off power to the robot system, pull out the power plug from the power
source. Be sure to connect the AC power cable to a power receptacle. DO
NOT connect it directly to a factory power source.
■
Before performing any replacement, turn OFF the Controller and related
equipment, and then pull out the power plug from the power source.
Performing any replacement with the power ON is extremely hazardous and may
result in electric shock and/or malfunction of the robot system.
CAUTION
■
Be careful not to apply excessive shock to the motor shaft when replacing the
motors. The shock may shorten the life cycle of the motors and encoder and/or
damage them.
■
Never disassemble the motor and encoder. A disassembled motor and encoder
will cause a positional gap and cannot be used again.
After parts have been replaced (motors, reduction gear units, brakes, timing belts, ball screw
spline unit, etc.), the Manipulator cannot operate properly because a mismatch exists
between the origin stored in each motor and its corresponding origin stored in the Controller.
After replacing the parts, it is necessary to match these origins.
The process of aligning the two origins is called “Calibration”.
Refer to
Maintenance: 13. Calibration
to execute the calibration.
Joint #4 Motor
U2 belt
U1 Belt
Содержание LS10-B
Страница 1: ...Rev 6 EM204R4257F SCARA ROBOT LS10 B series MANIPULATOR MANUAL ...
Страница 2: ...MANIPULATOR MANUAL LS10 B series Rev 6 ...
Страница 8: ...vi LS10 B Rev 6 ...
Страница 12: ...TABLE OF CONTENTS x LS10 B Rev 6 ...
Страница 14: ......
Страница 25: ...Setup Operation 1 Safety LS10 B Rev 6 13 LS10 B Figure LS10 B702S ...
Страница 65: ...Setup Operation 5 Motion Range LS10 B Rev 6 53 Standard model LS10 B S ...
Страница 66: ...Setup Operation 5 Motion Range 54 LS10 B Rev 6 Cleanroom model LS10 B C ...
Страница 67: ...Maintenance This volume contains maintenance procedures with safety precautions for LS10 B series Manipulators ...
Страница 68: ......
Страница 89: ...Maintenance 4 Cable LS10 B Rev 6 77 4 2 Wiring Diagrams 4 2 1 Signal Cable ...
Страница 90: ...Maintenance 4 Cable 78 LS10 B Rev 6 4 2 2 Power Cable ...