(1) Turn OFF the Controller.
(2) Install a hexagon socket head cap bolt into the hole corresponding to the setting angle,
and tighten it.
Joint Hexagon socket head cap
bolt (fully threaded)
The number
of bolts
Recommended
tightening torque
1
M8 × 10
1 bolt / side
12.3 N
⋅
m (125 kgf
⋅
cm)
(3) Turn ON the Controller.
(4) Set the pulse range corresponding to the new positions of the mechanical stops.
Be sure to set the pulse range inside the positions of the mechanical stop range.
Example: Using LS10-B602S
The angle of Joint #1 is set from
−
110
°
to +110
°
.
The angle of Joint #2 is set from
−
110
°
to +110
°
.
Execute the following commands from the [Command Window].
>JRANGE 1,
-72817
,
728177
' Sets the pulse range of Joint #1
>JRANGE 2,-
250331
,
250331
' Sets the pulse range of Joint #2
>RANGE
' Checks the setting using Range
-72817, 728177, -250311, 250311, -270336, 0,
-215040, 215040
(5) Move the arm by hand until it touches the mechanical stops, and make sure that the arm
does not hit any peripheral equipment during operation.
(6) Operate the joint changed at low speeds until it reaches the positions of the minimum
and maximum pulse range. Make sure that the arm does not hit the mechanical stops.
(Check the position of the mechanical stop and the motion range you set.)
Example: Using LS10-B602S
The angle of Joint #1 is set from
−
110
°
to +110
°
.
The angle of Joint #2 is set from
−
110
°
to +110
°
.
Execute the following commands from the [Command Window].
>MOTOR ON
' Turns ON the motor
>POWER LOW
' Enters low-power mode
>SPEED 5
' Sets at low speeds
>PULSE -72817,0,0,0
' Moves to the min. pulse position of Joint #1
>PULSE 728177,0,0,0
' Moves to the max. pulse position of Joint #1
>PULSE 327680,-250311,0,0
' Moves to the min. pulse position of Joint #2
>PULSE 327680,250311,0,0
' Moves to the max. pulse position of Joint #2
The Pulse command (Go Pulse command) moves all joints to the specified positions at
the same time. Specify safe positions after considering motion of not only the joints
whose pulse range have been changed, but also other joints.
In this example, Joint #1 is moved to 0
°
position where is close to the center of its
motion range (pulse value:
327680
) when checking Joint #2.
If the arm is hitting the mechanical stops or if an error occurs after the arm hits the
mechanical stops, either reset the pulse range to a narrower setting or extend the
positions of the mechanical stops within the limit.
EPSON
RC+
EPSON
RC+
NOTE
Содержание LS10-B
Страница 1: ...Rev 6 EM204R4257F SCARA ROBOT LS10 B series MANIPULATOR MANUAL ...
Страница 2: ...MANIPULATOR MANUAL LS10 B series Rev 6 ...
Страница 8: ...vi LS10 B Rev 6 ...
Страница 12: ...TABLE OF CONTENTS x LS10 B Rev 6 ...
Страница 14: ......
Страница 25: ...Setup Operation 1 Safety LS10 B Rev 6 13 LS10 B Figure LS10 B702S ...
Страница 65: ...Setup Operation 5 Motion Range LS10 B Rev 6 53 Standard model LS10 B S ...
Страница 66: ...Setup Operation 5 Motion Range 54 LS10 B Rev 6 Cleanroom model LS10 B C ...
Страница 67: ...Maintenance This volume contains maintenance procedures with safety precautions for LS10 B series Manipulators ...
Страница 68: ......
Страница 89: ...Maintenance 4 Cable LS10 B Rev 6 77 4 2 Wiring Diagrams 4 2 1 Signal Cable ...
Страница 90: ...Maintenance 4 Cable 78 LS10 B Rev 6 4 2 2 Power Cable ...