2016/08/25
Revision: 2
Page:
80
7.5 Cleaning time information
Structure
Item
Byte (Hex)
Value (Hex)
Header
1
0C
Parameter counter
1
02
Parameter
2
Cleaning time information
The parameter <cleaning time information> is two bytes Binary codes that indicate cleaning time or ink filling time.
The unit is second. (This time is total time not passage time or remains time.)
This parameter is added only when status code ST = 07H.
7.6 Ink information
Structure
Item
Byte(Hex)
Value(Hex)
Header
1
0Fh
Parameter total counter
1
10h
Parameter counter for 1 I/C
1
3h
Parameter
3 per 1 I/C
Ink information
The ink information order is Black1, Black2, Magenta, Cyan, ,Yellow
Each ink cartridge information is consisted of m1, m2, m3.
Ink information
code
m1
Ink cartridge name
01h: "Black Ink Cartridge"
03h: "Cyan Ink Cartridge"
04h: "Magenta Ink Cartridge"
05h: "Yellow Ink Cartridge"
0Bh: "Black#2 Ink Cartridge"
m2
Ink color
00H:Black
01H:Cyan
02H:Magenta
03H:Yellow
m3
Ink remain counter
cartridge in : ”i” (Always indicates “i”)
7.7 Loading path information
Structure
Item
Byte (Hex)
Value (Hex)
Header
1
10
Parameter counter
1
3
Parameter
3
01084E