3-18
CONFIDENTIAL
EMP-1825/EMP-1815/EMP-1810
SEIKO EPSON
Revision:C
3.3.8 Lens Shutter’s Operation Check
Flowchart 3-10 Lens Shutter’s Check
Start
1.
Replace
the
corresponding
cable.
2.
Replace
Photo
Interrupter.
Does
AV
Mute
function
start
/
stop,
when
closing
/
opening
the
shutter?
3.
Replace
Optical
Engine
and
MAB
set.
N
G
N
G
N
G
If
theAV
Mute
does
not
work
correctly,
apply
the
remedy
from
the
top
(1).
If
it
doesnot
work,
go
on
to
the
next
remedy.
For more information, refer to
4.3.4.2. "Removing the Lens Shutter B/Lens Shutter A/Photo Inter-
4.4.1 "Removing the Optical Engine and MAB (1) (MA Board Assy.)" (p. 20)
"Removing the Optical Engine and MAB (2) (Optical Engine)" (p. 42)
Содержание EMP-1815
Страница 1: ...Service Manual Data Projector EMP 1825 EMP 1815 EMP 1810 ...
Страница 9: ...Chapter 1 Product Specifications ...
Страница 16: ...Chapter 2 Theory of Operation ...
Страница 23: ...Chapter 3 Troubleshooting ...
Страница 44: ...Chapter 4 Disassembly Assembly ...
Страница 105: ...Chapter 5 Adjustment ...
Страница 113: ...Chapter 6 Appendix ...