4-30
CONFIDENTIAL
EMP-1825/EMP-1815/EMP-1810
SEIKO EPSON
Revision:C
Removing the IM Board Assy. (EMP-1825/1815 only)
4). Remove the screw (C.C.SCREW,3X6,F/ZN-3C) that secures the IM Board Assy.
5). Remove the three screws (C.B.P-TITE SCREW,2.5X10,F/ZN-3C) that secure the IM
Board Assy. and remove the IM Board Assy.
6). Disconnect the MA-IM Cable from the connector (CN1302) on the IM Board Assy.
7). Disconnect the SB-IM FFC Cable from the connector (CN1300) on the IM Board Assy.
8). Disconnect the USB Cable from the connector (CN30) on the USB Board Assy.
Figure 4-33.
IM Board Assy.
C.C.SCREW,3X6,F/ZN-3C
CN1302
CN1300
SB-IM FFC Cable
MA-IM Cable
CN30