3. Remove the nine screws (C.C.SCREW,3X6,F/ZN-3C) that secure the MA Board Assy.
4. Remove the screw (C.P.(S-P1)SCREW,4X6,F/ZN-3C) that secures the MA Board Assy.’s
GND.
5. Remove the screw (C.B.SCREW,3X6,F/NI) that secures the USB terminal, and remove the
MA Board Assy.
6. Remove the following parts from the MA Board Assy.
•
EMI Suppressor; C
•
Heat Sink;A x 3
•
Heat Sink;PW
•
PJ Lens Cover Cushion x2
Figure 4-21.
C.P.(S-P1)SCREW,
4X6,F/ZN-3C
MA Board Assy.
C.B.SCREW,
3X6,F/NI
Heat Sink;A
Heat Sink;PW
EMI Suppressor; C