4.3.4.2. Removing the Lens Shutter B/Lens Shutter A/Photo Interrupter
1. Remove the screw (C.B.P-TITE SCREW,2.5X10,F/ZN-3C) that secures the Lens Shutter B,
and remove the Lens Shutter B from the Upper Case Unit AJ together with the Lens Shutter
A and the Photo Interrupter.
2. Remove the Lens Shutter A and the Shutter Spring from the Lens Shutter B.
3. Remove the Photo Interrupter from the Lens Shutter B
4. Remove the SW Cable from the Photo Interrupter.
5. Remove the Lens Shutter Sheet from the Lens Shutter A.
Figure 4-16.
Lens Shutter B
Shutter Spring
Photo Interrupter
Lens Shutter Sheet
Lens Shutter A