Epson DFX-9000 Field Repair Guide
3/29/07
Adjustments
Printer Component,
Software Item,
LCD Display,
Printer Button
Page 174.
11. If the .40mm feeler gauge will easily fit between the
Print Head
and the
Platen
, the gap is too wide. Loosen
Screw B
about 1/8 of a turn. To adjust the gap, insert a flat blade screwdriver into the opening to the left of
Screw B
. Twist the screwdriver to change the gap. To decrease the gap, move the
Upper Angle Bar
downwards. Tighten
Screw B
when the adjustment is correct.
ScrewA
Screw B
Screw C
Upper Angle Bar