40
Code
Cause
Solution
E10
Motor stall, which may
be caused by blocked
propeller
Turn off power, then clean up the things
winding around the propeller. Test if the
propeller can be rotated by hand before
operation.
E11
The temperature of
motor is too high.
Stop operating the motor and wait until
the temperature falls within the normal
operating temperature range.
E12
The temperature of
circuit board is too
high.
Stop operating the motor and wait until
the temperature falls within the normal
operating temperature range.
E15
Failure was found
in the circuit board
temperature sensors.
Try to turn off the main power switch
and wait for 10 seconds then turn on the
switch again.
E16
Calibration
Abnormality of Current
Sensor
Please contact the dealer for help.
E21
Driver Communication
Fault
Please check whether the version of
Side Mount Control corresponds to the
motor version first. If not, please refer to
2.4 Version Setting for version switching.
If the version is correct, check the
communication cable connection and
restart the motor. If the problem still
arises, please contact the ePropulsion
authorized dealer for assistance.
E22
MCU Communication
Abnormality
Please restart to see if the error
disappears, if not, please contact your
dear for help.