Safety precautions 

ATTENTION 

All  the  safety  precautions  stated  in  this  guide  must  be  followed  at  all  times 

during  the  device  exploitation  and  maintenance.  Disobedience  to  the  stated 
safety  precautions  and  warnings  may  cause  the  device  malfunction,  threaten 

the  personnel’s  health  or  trigger  the  emergency  erasure.  The  manufacturer 
takes no responsibility in case of safety precautions violation. 

GROUNDING 

The device must be connected to a grounded power supply outlet by a three-
wire cable. Damage or disconnection of the grounding wire causes the risk of 

electric injuries. 

INPUT VOLTAGE 

The device is designed for a single-phase AC power supply, 220 V, 50 Hz. It is 
forbidden  to  connect  the  device  to  a  power  supply  having  parameters  other 

than specified. 

PREPARATION FOR HDD EXTRACTION OR DEVICE MAINTENANCE 

Before HDD extraction or device maintenance, switch the device into “Disarm” 

mode, disconnect the power supply and wait for 10 minutes. Only after these 
actions it is safe to open the device chassis. 

DEVICE COMPONENTS AND CIRCUITRY 

Tuning  or  replacing  any  component  of  the  device  is  forbidden.  Altering  the 

circuits or internal connections is also forbidden. 
Users  can  only  access  the  protected  HDDs  to  perform  their  maintenance  or 

replacement. 
For service or repair, the device must be returned to the manufacturer. 

REGULAR INSPECTION AND MAINTENANCE 

The  user  must  inspect  the  device  status  monthly  or  more  frequently.  It  is 
needed to check the frequency of “Charge” LED blinking on each block. Normal 

value  is  60-70  impulses  per  minute.  If  the  blinking  frequency  is  higher,  it 
means  the  key  components  of  the  device  have  changed  their  characteristics. 
This may cause the device malfunction or trigger the emergency erasure. 
The  device  must  be  tested  yearly  or  more  frequently.  The  testing  must  be 

performed in the manufacturer’s laboratory. 
 

 

Содержание Kolchuga

Страница 1: ...Protected external storage Kolchuga User guide...

Страница 2: ...extraction or device maintenance switch the device into Disarm mode disconnect the power supply and wait for 10 minutes Only after these actions it is safe to open the device chassis DEVICE COMPONENT...

Страница 3: ...04071 Ukraine www epos ua February2012 Ver 1 6 Sales and support EPOS Computer forensics and information security laboratory 44 Verkhniy Val str Kiev 04071 Ukraine Tel 380 44 425 2342 Fax 380 44 462 5...

Страница 4: ...3 Switching the Operation modes 8 4 Operation 9 4 1 Triggering by a key 9 4 2 Triggering by a wired button optional 9 4 3 Triggering by a wireless BUTTON optional 10 4 4 Triggering by a gsm module op...

Страница 5: ...y of protected HDDs 1 4 Interfaces SATA SAS IDE SCSI USB 3 0 Processing chamber dimensions for each HDD 150x118x29 mm Erasing magnetic field intensity inside the processing chamber 550 kA m Start up t...

Страница 6: ...e magnetized to full saturation The full destruction of the magnetic structure of the medium including service areas and bad sectors results in guaranteed erasing of all the data ever stored on it The...

Страница 7: ...comes active 7 Experimentally trigger the information erasing without HDDs inside the device by all available methods depending on your bundle By GSM module call the device number and select option 6...

Страница 8: ...0 Connect the interface and power cables to the HDD 11 Assemble the device in reverse order After power supply disconnection electric charge remains in the device circuits To prevent electric injuries...

Страница 9: ...from the device before GSM module reprogramming 2 Connect GSM module to a computer refer to GSM module guide included on a CD You may need to install the GSM module driver included on a CD 3 Run the G...

Страница 10: ...ser password 5 Enable the checkbox Apply Administrator password and set the password for administrator access and configuration protection Authorized users management Access the GSM module configurati...

Страница 11: ...your bundle There are three available methods Button on the back panel of the device Wireless button small button on the wireless control unit GSM module 6 Call the device number 7 Select item 8 in th...

Страница 12: ...e 4 1 TRIGGERING BY A KEY To trigger the information erasing by this method insert the key into the keyhole Erase and turn it 90 clockwise Triggering by a key is possible even when protected HDDs are...

Страница 13: ...calls are identified by the telephone number If the user is included in the authorized users list he she will be offered to enter the password If the user is not included in the authorized users list...

Страница 14: ...commended to test the probability of false triggering after the device installation in its final place BEFORE the HDDs installation 4 6 TRIGGERING BY AN ACCELEROMETER OPTIONAL The device may be option...

Страница 15: ...he protected HDDs the device sends the following messages to all the authorized users time ON where time is the erasing triggering time ON is the wired button triggering report Triggered by a wireless...

Страница 16: ...is the power restoration time is the power restoration report Upon accumulator battery discharge to 40 of its capacity the device sends the following messages to all the authorized users time 40 where...

Страница 17: ...in this case switch the operation mode to Disarm turn the device power off and on again and finally switch the operation mode to Arm 5 2 OPERATIONAL ENVIRONMENT The device is designed for exploitation...

Страница 18: ...hing to Arm mode the device does not get ready the indicator Ready does not light up but indicators Power and Charge glow Probable reason Chassis intrusion sensor is open Solution 1 Disconnect the dev...

Отзывы: